Skip to main content
. 2023 Mar 2;24(5):4866. doi: 10.3390/ijms24054866

Table 3.

Agreement between MMR IHC status and MSI PCR testing.

MSI PCR
All EC (n = 99) POLEwt EC (n = 83)
MSI-high MSS MSI-high MSS
MMR IHC status MMRd 31 8 25 7
MMRp 3 57 3 48
Sensitivity % 91.2
(95% CI: 76.3–98.1) *
89.3
(95% CI: 71.8–97.7) *
Specificity % 87.7
(95% CI: 77.2–94.5) *
87.3
(95% CI: 75.5–94.7) *
Accuracy % 88.9
(95% CI: 81.0–94.3) *
88.0
(95% CI: 79.0–94.1) *
PPV % 79.5
(95% CI: 63.5–90.7) *
78.1
(95% CI: 60.0–90.7) *
NPV % 95.0
(95% CI: 86.1–99.0) *
94.1
(95% CI: 83.8–98.8) *

* Exact Cis.