Skip to main content
. 2023 Feb 26;23(5):2583. doi: 10.3390/s23052583

Table 5.

Correlation factors in the range from 100 kHz to 964 kHz for a motor with slight rotor misalignment.

Reference TF Pearson’s ρ Spearman r
Max 0.8676 0.8974
+ sigma 0.9289 0.9251
mean 0.9581 0.9733
- sigma 0.9655 0.9726
Min 0.9476 0.9698