Skip to main content
. 2023 Mar 13;82(7):638–650. doi: 10.1007/s40042-023-00763-4

Table 4.

The list of systems for KISTI remote control room

Server #1 Server #2 Server #3 Server #4
IP address

150.183.246.101

(belle2roc.kisti.re.kr)

150.183.246.102 150.183.246.106 150.183.246.107
OS Windows 7 Professional K Windows 7 Professional K Windows 10 Pro Windows 7 Professional K
CPU Intel(R) Xeon(R) CPU E5-1650 @ 3.20 GHz Intel(R) Core(TM) i7-6700 K CPU @ 4.00 GHz

Intel(R) Core(TM) i7-3770 K CPU

@ 3.50 GHz

Intel(R) Core(TM) i5-2390 T CPU

@ 2.70 GHz

Memory 16 GB 16 GB 16 GB 8 GB
System 64bit OS 64bit OS 64bit OS 64bit OS
Purpose for online shift Monitoring, controlling RC (Run Control) panel Connecting SpeakApp and Rocket.Chat, recording e-log Backup for two people shift
Purpose for offline shift Monitoring, recording e-log, issuing JIRA [8] ticket, connecting KEKCC Backup for two people shift