Table 5.
Laryngoscopy and intubation data with McCoy and McGrath laryngoscopes
Parameter | McCoy n=37 | McGrath n=37 | P value |
---|---|---|---|
Adjuncts (GEB) | 16 (43.2) | 2 (5.4) | <0.001 |
Optimisation manoeuvres | |||
BURP | 10(27.0) | 2(5.4) | 0.002 |
OELM | 12(32.4) | 5(13.5) | |
None | 15(40.5) | 30(81.1) |