Rate of Spinal Cord Stimulation (SCS) Complications

Authors Complication Incidence Notes
Kumar,55 Brazzelli,56 Cameron,58 Mekhail57 Lead migration 13.2–22.6% More common in cervical placement
Mekhail,57 Cameron,58 Kumar55 Lead Fracture 5.7–6%
Turner,60 Cameron,58 Kumar59 Battery Failure 0–10.2%
Mekhail57 Pain at IPG site 12%
Eldabe54 Infection 4–10% More frequent at IPG implant site
Cameron58 Skin Erosion 0.2%
Simopolous64 Post Dural Persistent Headache Less than 1%
Cameron58 Epidural Hematoma 0.03%