Table 2.

Quantitative metrics (CNR, SC, EPI and computation time) evaluating denoising performance of MM-despeckle TV, Lee-diffusion filter and SAR BM3D methods when applied to hippocampus image in Fig. 3.

Methods CNR SC EPI PSNR Time (s)
Noisy Data 0.82 1.47 - 19.33 -
100-avg Data 2.15 0.7 - - -
MM-despeckle TV 2.8 0.7 0.75 28.13 284.72
SAR BM3D 1.55 0.9 0.53 25.11 452.07
Lee-diffusion filter 2.77 0.71 0.08 27.61 8.53
Log Normal TV 2.92 0.73 0.62 26.76 12.76