Table 8.

The result of the two-piecewise Cox regression model and linear regression model

Renal composite endpoint (HR, 95%CI, P )
Fitting model by two-piecewise Cox regression
 Inflection point of ALB 4.3 g/dL
   ≤ 4.3 g/dL 0.42 (0.32, 0.56)  < 0.001
   > 4.3 g/dL 6.11 (0.98, 38.22) 0.05
P for log-likelihood ratio test  < 0.05
Renal function decline (β, 95%CI, P)
Fitting model by two-piecewise linear regression
 Inflection point of ALB 4.1 g/dL
   ≤ 4.1 g/dL -2.79 (-3.62, -1.96)  < 0.001
   > 4.1 g/dL 0.02 (-1.79, 1.84) 0.98
P for log-likelihood ratio test  < 0.05

We adjusted age, BMI, gender, SBP, diabetes, hypertension, history of CVD, eGFR, UPCR, ALB, use of RAAS inhibitor, urinary occult blood, use of calcium channel blocker, and use of diuretics