Skip to main content
. 2023 Jan 21;270(4):2217–2229. doi: 10.1007/s00415-023-11569-6

Table 5.

Summary of the stimulation settings of patients included in the study, at their last available appointment

Device Left VIM Right VIM Left GPi Right GPi
Pt1 Boston scientific

3 + ,2-

1.0 mA

40 msc

119 Hz

6-,7 + ,

1.0 mA

40 msc

119 Hz

case + ,10-

1.2 mA

120 msc

119 Hz

14-,case + 

1.2 mA,

120 msc,

119 Hz

Pt2 Medtronic Activa RC

case + ,2-

2.6 V

60 msc

125 Hz

case = 6-,5-

2.0 V

60 msc

125 Hz

case + ,10-,

1.0 V,

210 msc,

125 Hz

case + ,15-

1.2 V

210 msc

125 Hz

Pt 3 Boston scientific

case + , 2-

1.3 mA

60 msc

119 Hz

case + ,6-

1.4 mA

60 msc

119 Hz

case + 10-

1.0 mA,

210 msc,

119 Hz

case + ,13-

1.0 mA

210 msc

119 Hz

Pt 4 Boston scientific

case–,6-,5-

4.3 mA

40 msc

185 Hz

case + ,14-,13-

4.5 mA

50 msc

185 Hz

Pt 5 Boston scientific

case + , 1-

5.0 mA

120 msc,

185 Hz

8 + ,5-

4.7 mA

90 msc

185 Hz

Case + , 13-,

2.0 mA

90 msc

185 Hz

Pt 6 Boston scientific

case + ,1-,2-,3-

4.5 mA

60 msc

180 Hz

case + ,5-,6-

2.5 mA

60 msc

180 Hz

Pt 7 Boston scientific

case + ,2-

1.6 mA

40 msc

119 Hz

case + ,6-

2.9 mA,

60 msc

119 Hz

case + 10-

2.5 mA

210 mcs

119 Hz

case + 14-

1.8 mA

210 msc

119 Hz

Pt 8 Boston scientific

8 + ,5-

1.5 mA

60 msc

119 Hz

11-,10,case + 

2.7 mA

40 msc

119 Hz

case + ,14-

3.8 mA,

120 msc,

119 Hz

Pt 9 Medtronic Activa RC

12-,case + 

3.1 V

60 msc

125 Hz

case + ,9-

2.6 V

60 msc

125 Hz

2 + ,1–0-

2.4 V

120 msc

125 Hz

6 + ,5-,4 + ,

2.2 V,

120 msc,

125 Hz