Skip to main content
. 2023 Mar 8;11:1055860. doi: 10.3389/fbioe.2023.1055860

TABLE 5.

The RMSE and the median error with range from minimal to maximal error for the ACL and the PCL origin and insertion.

Origin ACL (femur) PCL (femur) Insertion ACL (tibia) PCL (tibia)
RMSE (in mm) 2.70 2.25 RMSE (in mm) 6.29 2.97
Error (in mm) (range) 2.02 (0–3.84) 2.54 (0–3.14) Error (in mm) (range) 5.65 (4.15–8.66) 2.69 (0–4.83)