Skip to main content
. 2022 Dec 6;36(2):725–738. doi: 10.1007/s10278-022-00744-2

Table 2.

Peak Signal to Noise Ratio (PSNR) for three different imaging modes (T1 and PD) at different levels of noise for different methods

Methods/Noise (dB,%) (15, 3) (12, 6) (10, 10) (6, 15) (3, 20) (1 ,25) (15, 3) (12, 6) (10, 10) (6, 15) (3, 20) (1 ,25)
T1-Weighted PD-Weighted
Noisy 38.47 28.22 22.24 18.90 17.25 16.53 38.21 28.74 22.60 20.27 18.22 16.92
ONLM 44.98 37.17 35.53 33.31 30.16 24.99 42.70 37.16 33.16 34.10 30.55 28.26
AONLM 43.23 35.54 30.13 25.85 23.12 20.06 41.79 35.94 30.10 27.64 23.09 20.37
PRINLM 45.88 39.86 35.99 33.35 29.60 23.88 45.83 38.86 35.86 30.49 31.66 31.08
MRNLM 44.85 37.32 34.95 33.11 30.36 25.04 42.10 36.69 32.62 34.00 29.46 26.84
DnCNN 41.02 33.38 29.90 27.19 25.00 22.66 35.70 33.27 28.40 27.33 25.25 23.71
DIP 45.24 37.59 32.23 28.45 25.98 23.55 45.19 37.77 30.35 29.14 26.52 24.55
RED-WGAN 44.60 38.70 33.68 29.19 25.48 23.56 38.92 37.74 34.66 30.07 26.97 23.87
GenMRIDenoiser 47.09 41.21 37.12 34.09 32.28 30.03 46.61 39.50 35.72 33.66 31.13 28.80