Skip to main content
. 2022 Nov 23;36(2):574–587. doi: 10.1007/s10278-022-00732-6

Table 4.

Average symmetric surface distance (ASSD) calculated over deformed pelvic masks and the ground-truth masks for the different variants of DIRNet models. Results are given for the entire DIRNet models for the cervix, bladder, and rectum

Average symmetric surface distance (ASSD)
Cervix (mean ± SD) Bladder (mean ± SD) Rectum (mean ± SD)
Before registration 4.00 ± 1.82 mm 2.68 ± 1.09 mm 7.70 ± 3.90 mm
SimpleElastix 2.94 ± 0.78 3.26 ± 0.74 3.04 ± 1.50
DIRNet Base model 1.85 ± 0.45 1.52 ± 0.86 1.97 ± 0.78
2 2.63 ± 1.01 3.46 ± 0.90 3.70 ± 2.75
3 2.86 ± 0.65 2.87 ± 2.37 2.92 ± 0.94
4 1.61 ± 0.46 1.17 ± 0.15 1.06 ± 0.42