Skip to main content
. 2023 Mar 25;53(2):89–98. doi: 10.4041/kjod22.183

Table 3.

Results of 3-point bending tests

Measured variables MD between retrieved-new (N) 95% CI p-value
1 mm activation −0.06 (−0.15, 0.02) 0.152
2 mm activation −0.03 (−0.10, 0.05) 0.499
3 mm activation
Anterior segment −0.18 (−0.29, −0.07)* 0.002
Posterior segment −0.76 (−0.99, −0.53)* < 0.001
3.1 mm activation
Anterior segment −0.20 (−0.31, −0.09)* < 0.001
Posterior segment −0.75 (−0.98, −0.52)* < 0.001
Bending modulus
Anterior segment −2.67 (−4.11, −1.22)* < 0.001
Posterior segment −0.67 (−3.83, −0.94)* 0.023

Mean difference (MD) of measurements and 95% confidence interval (CI) of the difference between retrieved and new specimens (defined as the measurement on the retrieved minus the measurement on the new).

*Statistically significant at 0.05 level.