Summary of Operating data from the power plant.

S/N Variables Quantities
1 Ambient Temperature (0C), T1 20–35
2 Ambient Relative Humidity (%), ɸ 41.02–92
3 Turbine Exhaust Temperature (0C), T4 531.5–549.3
4 Compressor Inlet Pressure (bar), p1 1.011–1.013
5 Compressor Outlet Pressure (bar), p2 10.898–11.071
6 Mass flow rate of air (kg/s), m˙a 480.34–514.40
7 Mass flow rate of fuel (kg/s), m˙f 10.28–11.41
8 Net Power output (MW), Pnet 140.869–159.272