Table 3.
Summary of Operating data from the power plant.
S/N | Variables | Quantities |
---|---|---|
1 | Ambient Temperature (0C), T1 | 20–35 |
2 | Ambient Relative Humidity (%), ɸ | 41.02–92 |
3 | Turbine Exhaust Temperature (0C), T4 | 531.5–549.3 |
4 | Compressor Inlet Pressure (bar), p1 | 1.011–1.013 |
5 | Compressor Outlet Pressure (bar), p2 | 10.898–11.071 |
6 | Mass flow rate of air (kg/s), | 480.34–514.40 |
7 | Mass flow rate of fuel (kg/s), | 10.28–11.41 |
8 | Net Power output (MW), Pnet | 140.869–159.272 |