Skip to main content
. 2023 Mar 17;9(3):e14645. doi: 10.1016/j.heliyon.2023.e14645

Table 4.

Model validation results for installed data.

S/N Parameters Design Model Deviation %Error
1 Net Power Output (MW) 153 151.645 1.355 0.885621
2 Net Heat Rate(kJ/kWh) 10,528 10,858 −330 −3.1345