Skip to main content
. 2023 Mar 27;22:31. doi: 10.1186/s12938-023-01094-y

Table 3.

A comparison of internal tibial rotations predicted by FD models and experimentally measured results by Neri et al. [26] under 5 Nm IR (internal rotation) torque

Knee state Internal rotation (IR) range
FD model (°) Neri et al. [26] (°)
Intact 2.5 to 12 (range 9.5) 0 to 12.1 (range 12.1)
ACL-sectioned 4.9 to 13.8 (range 8.9) 2.5 to 14 (range 11.5)
ACL-reconstructed alone (ACLR) 4.4 to 12 (range 7.6) 2 to 12.2 (range 10.2)
ACLR combined with anterolateral ligament reconstruction (ACLR + ALLR) 4.1 to 11 (range 6.9) 0.5 to 12.1 (range 11.6)
ACLR combined with MacIntosh reconstruction (ACLR + Mac) 3.9 to 10.5 (range 6.6) − 1 to 10.1 (range 11.1)
ACLR combined with Ellison reconstruction (ACLR + Ell) 3.9 to 12 (range 8.1) 0.5 to 12.8 (range 12.3)
ACLR combined with deep-Lemaire reconstruction (ACLR + DL) 3.3 to 12.5 (range 9.2) − 1.9 to 9.8 (range 11.7)
Average of IR range (mean ± SD) Range 8.1 ± 1.1 Range 11.5 ± 0.7