Skip to main content
. 2023 Mar 20;11(3):944. doi: 10.3390/biomedicines11030944

Table 4.

Comparison of Predictive performance of regression models.

Predictive Performance of Regression Model Pairwise Comparison of ROC Curves
Model AUC [95% CI] Standard Error p-Value z p-Value
Unadjusted Model 0.79 [0.70–0.87] 0.04 <0.001 *** 2.356 0.0185
Adjusted Model 0.89 [0.82–0.95] 0.03 <0.001 ***

*** p < 0.001.