Skip to main content
. 2023 Mar 15;13(3):386. doi: 10.3390/bios13030386

Table 2.

Comparison of various electrochemical biosensors.

Sr. No. Composition of Electrode Detection Method Method of Immobilization LOD
(µM)
Linear Range (µM) Optimum pH Optimum Temperature (°C) Response Time (Second) Storage Life (Days) Samples References
1 AChE-ChO/GO-IL/GCE ADPSV Adsorption 8.85 × 10−4, 1.352 × 10−3 5 × 10−3–1 × 10−6 7.4 NR NR 90 Serum [7]
2 AChE-ChO/GO-AuNPs-CS/Fe3O4–TiO2@NH2/GCE ECL Cross-linking 0.002.2 6.7 × 10−3 –0.92 × 103 8 NR NR 15 Serum [8]
3 AChE-ChO/QDs/rGO/GCE ECL, CV Cross-linking 8.8, 4.7 10–210, 10–250 9.0 NR NR 7 Serum [9]
4 AChE-ChO/a PDDA/ZnO/MWCNTs/PGE CV Adsorption 0.3 1.0–0.8 × 103, 1.0–103 NR 50 60 90 Serum [10]
5 AChE-ChO/c PPy-PVS/Pt CV Cross-linking 5.0 × 10−3 10−5–10−3 9.0 65 200 NR Artificial blood [11]
6 AChE-ChO/MWCNT-MnO2/rGO/Au CV Cross-linking 0.1 0.1–1.00 7.4 35 NR 90 Serum [12]
7 AChE-ChO/MOF/PtNPs/Au DPV Covalent attachment 0.01 0.01–500 7.4 30 NR 120 Serum [13]
8 AChE-ChO/CS/Fe@AuNPs/Au SWV Cross-linking 5 × 10−2 5.0 × 10−3–400 7.0 30 3 90 Serum [14]
9 AChE-ChO/rGO/PtNP/ITO CV Cross-linking 5 × 10−3 5.0 × 10−3−700 7.0 35 4 120 Serum [15]
11 AChE-ChO/Fe2O3/rGO/PEDOT/FTO EIS Cross-linking 4.0 × 10−3 0.004–800 7.0 30 3 90 Serum [16]
12 AChE-ChO/AuNPs/pTTB/SPCE CA Covalent attachment 0.0026 0.7 × 10−3 −1.5 × 103 NR NR NR NR Serum [17]
13 AChE-ChO/CDs-APTES/CPE CV Cross-linking 5.0 × 10−3 10−5−10−2 7.0 60 200 NR Artificial blood [18]
14 AChE/PANI-Nano-ZSM−5/GCE SWV Entrapment 0.1 1.0–103 7.4 NR NR 15 - [33]
15 AChENPs/ChONPs/GONS/PtNPs/PGE CV Adsorption 0.001 0.001–200 7.5 35 3 180 Serum This work