Skip to main content
. 2023 Feb 27;10(3):475. doi: 10.3390/children10030475

Table 3.

Accuracy of Evenson’s cut-points to estimate MVPA and SB in children and adolescents with disabilities.

Group Variable Sensitivity
(%)
Specificity
(%)
AUC Correctly Classified (%) SE
Sedentary
(<25 counts·15 s−1)
Y 75 90 0.825 85 0.0435
VM 59 100 0.797 86 0.0441
Moderate-to-vigorous
(≥574 counts·15 s−1)
Y 67 91 0.790 88 0.0728
VM 92 59 0.758 63 0.0500

AUC, area under the curve; VM, vector magnitude; SE, standard error.