Abstract
Goal-directed fluid therapy (GDFT) is usually recommended in patients undergoing major surgery and is essential in enhanced recovery after surgery (ERAS) protocols. This fluid regimen is usually guided by dynamic hemodynamic parameters and aims to optimize patients’ cardiac output to maximize oxygen delivery to their vital organs. While many studies have shown that GDFT benefits patients perioperatively and can decrease postoperative complications, there is no consensus on which dynamic hemodynamic parameters to guide GDFT with. Furthermore, there are many commercialized hemodynamic monitoring systems to measure these dynamic hemodynamic parameters, and each has its pros and cons. This review will discuss and review the commonly used GDFT dynamic hemodynamic parameters and hemodynamic monitoring systems.
Keywords: Goal-directed fluid therapy, fluid resuscitation, pulse pressure variation, pleth variability index, stroke volume variation, aortic blood flow peak velocity variation, hemodynamic monitor, Flotrac, esophageal doppler, echocardiogram, LiDCO, ClearSight, PiCCO, enhanced recovery after surgery protocol
Introduction
Fluid resuscitation is critical during perioperative periods to ensure vital organs receive adequate oxygen perfusion. Especially since patients usually fast for 8 hours before surgery, which leads to dehydration [1]. Poor intraoperative fluid resuscitation can lead to poor patient outcomes [2].
Traditionally, intravenous (IV) fluid regimens are “liberal,” meaning high fluid amounts are given intraoperatively. In abdominal surgery, that amount is up to 7 liters (L) of fluids. However, these regimens lead to a weight gain of 3 to 6 kilograms, which suggests fluid overloading [3]. Other problems associated with liberal regimens include pulmonary complications [4,5], prolonged wound healing [6], and bowel edema causing prolonged ileus [7]. Moreover, hypervolemia may lead to an increase in atrial natriuretic peptide release from the heart, which enhances the deterioration of endothelial glycocalyx, a vital part of the vascular permeability barrier. This leads to vascular barrier loss and an increase in interstitial edema [8]. On the other hand, in patients undergoing low- to moderate-risk surgeries, a liberal fluid approach may be beneficial. For example, Holte et al. showed that patients who underwent laparoscopic cholecystectomy, when given 40 ml/kg IV fluids instead of 15 mL/kg IV fluids, had significantly improved postoperative pulmonary function, with less nausea, dizziness, and fatigue [9].
More recently, major surgeries and enhanced recovery after surgery protocols (ERAS) have been adopting more “restrictive” IV fluid regimens. In previous studies, intraoperative restrictive fluid regimens varied from 1.0 to 2.7L in abdominal surgeries [10]. While these regimens may avoid the side effects of the liberal method, it may cause hypotension leading to organ damage. For example, The Restrictive versus Liberal Fluid Therapy in Major Abdominal Surgery (RELIEF) trial, which randomized 3,000 patients to a liberal fluid regimen vs a restrictive fluid regimen, showed an increase in acute kidney injury (8.6% vs 5.0%). However, there is no difference in the rate of disability-free survival at one year. Other studies have shown that restrictive fluid regimens do have significant benefits in major surgeries. For example, multiple studies have shown that restrictive fluid regimens decrease postoperative ileus recovery in colon resections [11,12], and in the length of stay as well as 60-day surgical complications in patients who underwent hyperthermic intraperitoneal chemoperfusion [13].
While liberal and restrictive fluid regimens have pros and cons, the definition of “liberal” or “restrictive” is arbitrary and depends on individual institutions or clinicians. Therefore, Goal-Directed Fluid Therapy (GDFT) has been utilized in several surgeries to avoid hypotension and fluid overloading by giving the “just right” fluid amount. This review aims to evaluate the current evidence and literature on commonly used dynamic parameters and hemodynamic monitor systems, which have been used for multicenter GDFT randomized clinical trials (RCT), and verified perioperatively in other studies (Table 1 and Table 2).
Table 1. Commonly Used Dynamic Hemodynamic Parameters and Monitors.
| Static Hemodynamic Parameters | Dynamic Hemodynamic Parameters | Hemodynamic Monitors |
| Central Venous Pressure (CVP) | Pulse Pressure Variation (PPV) | Flotrac™ |
| Mean arterial pressure (MAP) | Stroke Volume Variation (SVV) | LidCO™ |
| Cardiac Output (CO) | Pleth Variability Index (PVi) | Masimo Radical 7 Pulse CO-Oximeter™ |
| Aortic blood flow peak velocity variation (ΔVpeak) | ClearSight™ | |
| PiCCO™ | ||
| Esophageal Doppler | ||
| Transthoracic and Transesophageal Echocardiogram |
Table 2. Commonly Used Commercialized Hemodynamic Monitor Systems.
| Monitor | Company | Measured Parameters | Technique |
| Flotrac™ | Edwards Lifesciences | CO, SV, SVV, and SVR | Arterial pulse contour analysis |
| LiDCO™rapid | Masimo | SV, SVR, SVV, oxygen delivery, and PPV | Arterial pulse power analysis |
| ClearSight™ | Edwards Lifesciences | CO, SV, SVV, SVR, and MAP | Arterial pulse contour analysis |
| Radical 7 Pulse CO-Oximeter™ | Masimo | PVi and Perfusion Index | Plethysmograph waveform analysis |
| PiCCO™ | Pulsion Medical System | CO, CI, ejection fraction, global end-diastolic volume, global ejection fraction, intrathoracic blood volume, and extravascular lung water | Thermodilution |
| Esophageal Doppler | Deltex Medical | Aortic blood flow | Ultrasound |
| Echocardiogram | Multiple Vendors | VTI and cardiac blood flow | Ultrasound |
What is Perioperative Goal-Directed Fluid Therapy?
Perioperative GDFT aims to maximize oxygen delivery to tissue by optimizing cardiac output (CO) through fluid resuscitation. Optimal cardiac output is defined as the top of the Frank-Starling preload-stroke volume curve [14]. At max capacity, which is at the top of the curve, the increase in end-diastolic pressure increases the stroke volume (SV) less when compared to the lower part of the curve. Thus, less “elastic.” The ideal fluid status will be at max capacity where the increase in end-diastolic volume does not change the SV significantly (Figure 1).
Figure 1.

Frank-Starling Curve. At the curve plateau, the end-diastolic volume increase does not increase the stroke volume as much. In contrast, at the lower part of the curve, the same amount of increase in end-diastolic volume increase the stroke volume much greater.
Current Evidence for Goal-Directed Fluid Therapy
Multiple large-scale RCTs have shown GDFT’s benefits in the perioperative setting. Additionally, smaller studies demonstrated that GDFT has clinical benefits in non-cardiac, cardiac, and vascular surgery high acuity patients [15-18]. PubMed and clinicaltrials.gov searches with the terms “Goal-Directed Fluid Therapy” and “multicenter randomized clinical trials” are summarized in Table 3. On the other hand, pushing the patient to the top of the Frank-Starling curve will lead to increased natriuretic peptides secreted by the heart, which provokes vasodilation, capillary leakage, and diuresis [19].
Table 3. Multicenter Randomized Control Trials.
| n | Types of Surgery | Parameter | Monitor | Results | |
| Sá Malbouisson et al. [38] | 84 | Open major surgery | PPV | DX 2020™ | Decrease in postoperative complications and hospital length of stay |
| Brandstrup et al. [123] | 150 | Elective colorectal surgery | SV | Esophageal Doppler | No significant differences in postoperative complications |
| Phan et al. [124] | 100 | Major colorectal surgery | SV index | Esophageal Doppler | No difference in length of stay and postoperative complications |
| Aaen et al. [125] | 312 | Emergency surgery for obstructive bowel disease or GI perforation | SV | Flotrac™ and EV 1000™ | No difference in major complications and death within 90 days, increase in hospital length of stay |
| De Waal et al. [126] | 482 | High risk elective, abdominal surgery | CI and SVV | Flotrac™ and Vigileo™ | No difference in the number of minor complications, hospital length of stay, PACU/ICU length of stay or grading of complications |
| Davies et al. ClearNOF trial [94] | 240 | Orthopedics Surgery | SV | ClearSight™ | No reduction in complications; however, a potential reduction in length of stay |
| Stens et al. COGUIDE trial [92] | 175 | Moderate risk abdominal Surgery | PPV, MAP, and CI | Nexfin™ (ClearSight™) | No reduction in complication rates |
| Sandham et al. [127] | 1994 | Urgent or elective major abdominal, thoracic, vascular, or hip-fracture surgery | Oxygen-delivery index, CI, MAP, pulmonary-capillary wedge pressure, HR, Hct | PAC | No benefit in care directed by PAC |
| Pearse et al. OPTIMISE trial [20] | 734 | Major abdominal surgery | SV | LiDCOrapid™ | No reduction in complications and 30-day mortality but updated meta-analysis was associated with a reduction in complication rates. |
| Calvo-Vecino et al. FEDORA trial [23] | 450 | Major abdominal, urological, gynecological, or orthopedic surgery | SV, CI, and MAP | Esophageal Doppler | Reduced postoperative complications and hospital length of stay in low to moderate risk patients |
| Pestaña et al. POEMAS Study [128] | 142 | Open colorectal surgery, gastrectomy, or small bowel resection | MAP and CI | NICOM™ | No decrease in the incidence of overall complications or length of stay |
| Voldby et al. GAS-ART trial [129] | 310 | Urgent gastrointestinal surgery due to gastrointestinal perforation or obstructive bowel disease | SV | Flotrac™ and EV 1000™ | Ongoing currently |
| Salzwedel et al. [130] | 160 | Elective abdominal surgery including general, gynecological, and urological surgery | PPV, CI, and MAP | ProAQT™ | Decrease in complications, no change in length of stay in hospital or PACU, no change in return of bowel function time |
| Weinberg et al. [131] | 48 | Elective major liver resection | SVV | Flotrac™ and EV 1000™ | No change in length of hospital stay or fluid related complications |
| Parke et al. [132] | 750 | Cardiac surgery | SVV | Flotrac™ and EV 1000™ | No differences in ICU stay time, development of organ dysfunction, quality of life or disability-free survival |
| Scheeren et al. [133] | 64 | High risk surgery | SVV and SV | Flotrac™ | Decreases postoperative wound infections |
| Diaper et al. [134] | 401 | Major abdominal, urological, or vascular surgery via open laparotomy | Stroke volume index, MAP, and PPV | LiDCO™ | No change in moderate-to-severe postoperative complications |
| Peng et al. FAB trial [135] | 80 | Spinal or sacral surgery | SVV | Flotrac™ and Vigileo 3.0™ | Arterial and gastric intramucosal pH were higher, decrease time to flatus. No differences in the length of hospital stay, complications or mortality |
| Weinberg et al. [136] | 52 | Pancreaticoduodenectomy | SVV, MAP, and CI | Flotrac™ and EV 1000™ | Decrease complication rates and length of hospital stay |
| Olivier Fischer et al. OPVI trial [27] | 447 | Hip or knee arthroplasty | PVi | Radical 7 Pulse CO-Oximeter™ | No change in hospital length of stay, serious postoperative cardiac complications, acute postoperative renal failure, troponin Ic concentration and lactate level |
| Edwards et al. OPTIMISE II trial [116] | 2502 | Resection of colon, rectum or small bowel, pancreas and bowel, stomach (non-obesity surgery), resection of esophagus, obesity surgery and other surgery involving gut resection | SV and SVV | Flotrac™ and EV 1000™ or ClearSight™ | Ongoing |
The largest GDFT multicenter RCT to date, the Optimization of Cardiovascular Management to Improve Surgical Outcome (OPTIMIZE) trial, randomized 734 high-risk adult patients undergoing major gastrointestinal surgeries. The GDFT group which used LiDCO™rapid (LiDCO Ltd, Cambridge, UK) as a monitor to guide fluid resuscitation had lower 30-day moderate or major complications and mortality (36.6% vs 43.4%) when compared to control. Though there was no difference in morbidity on day 7; infection, critical care-free days, and all-cause mortality at 30 days; all-cause mortality at 180 days; length of hospital stay [20]. Serum biomarkers from participants in the OPTIMIZE trial also showed no evidence of GDFT induced cardiac damage, as there was no elevation of troponin I concentration and N-terminal pro-brain natriuretic peptide [21]. Furthermore, a sub-study of the OPTIMIZE trial showed GDFT reduced health care costs [22]. Another multicenter RCT on GDFT, the FEDORA trial, randomized 450 low- to moderate-risk patients undergoing major abdominal, urological, gynecological, or orthopedic surgery to GDFT-guided by esophageal doppler or control groups. The FEDORA trial showed that patients in the GDFT group had fewer moderate to severe complications, such as acute kidney injury, pulmonary edema, and respiratory distress syndrome (8.6% vs 16.6%), and a shorter length of stay. However, there was no change in mortality [23].
Conversely, some studies have shown that GDFT lacks benefits. For instance, Gómez-Izquierdo et al. demonstrated that GDFT using esophageal doppler did not decrease the incidence of postoperative ileus in a RCT of 128 patients; even though it did increase CO and SV, and reduced perioperative IV fluids administration [24]. Moreover, Challand et al. showed no difference in discharge readiness and length of stay between patients who underwent major colorectal surgery in the GDFT group guided by esophageal doppler and the control group [25]. Besides abdominal surgeries, GDFT has been shown to lack effect in major vascular surgeries. Bisgaard et al. showed that in patients who underwent open elective abdominal aortic surgery, GDFT-guided by LiDCO™plus (LiDCO Ltd, Cambridge, UK) did not decrease postoperative complications or length of stay in the intensive care unit [26]. Additionally, very recently, Fischer et al. demonstrated in a RCT involving 447 intermediate-risk patients who underwent hip or knee arthroplasty that GDFT-guided by the Pleth Variability Index (PVi) had no effect in hospital stay, acute renal failure, and cardiac complications when compared to the control group [27].
While there are currently mixed GDFT trial results, more large-scale multicenter trials with a heterogeneous patient population may help resolve debates about its clinical benefits. Two notable differences in all these clinical trials are that they use different fluid responsiveness parameters and monitoring systems to guide fluid resuscitation.
Dynamic Parameters for Goal-Directed Fluid Therapy
The criterion standard of CO measurement remains using intermittent thermodilution with a pulmonary artery catheter (PAC). However, this measurement requires a PAC, making it impractical in many perioperative settings. As such, there are many CO surrogates and parameters developed to measure a patient’s fluid status and SV as defined by “static” and “dynamic.” These parameters are summarized in Table 1.
Although CVP is traditionally used as a static parameter to assess fluid responsiveness, multiple studies showed that it is unreliable [28]. In contrast, dynamic parameters were shown to estimate fluid responsiveness and status with reasonable accuracy [29-32].
Dynamic Parameters and the Frank-Starling Curve
These dynamic parameters depend on the Frank-Starling relationship. Under the relationship, the left ventricle (LV) SV changes due to intrathoracic pressure. This is because increased intrathoracic pressure compresses the right ventricle (RV), which decreases RV preload. If a patient’s fluid status is at the Frank-Starling curve plateau, respiratory pressure will have little effect on the RV preload. Thus, the RV preload respiratory variations will be low, and there will be no effect on the LV SV [33]. Because the LV SV and arterial compliance correlate with the arterial pressure, thus arterial pressure parameters, such as pulse pressure (PP), correlate with the LV SV variations.
As shown in Figure 2a and b, the arterial wave area under the curve (AUC) is the LV SV, whereas the wave peak is the systolic blood pressure (SBP) and the wave trough is the diastolic blood pressure (DBP). PP equals SBP – DBP. Both LV SV and PP vary during the respiration cycle (Figure 2d). If a patient is at the Frank-Starling curve plateau, both the arterial pressure AUC and the PP will have minimal variations during the respiration cycle. Figure 2c shows the pulse oximetry plethysmography which also correlates with the arterial pressure waves and thus also oscillates during the respiratory cycle. In the section below we will discuss the four commonly used fluid responsiveness dynamic parameters for GDFT guidance: pulse pressure variation (PPV), pleth variability index (PVi), stroke volume variation (SVV), and aortic blood flow peak velocity variation (ΔVpeak).
Figure 2.

PPV and SVV calculations. A-D, EKG, arterial pressure, pulse oximetry plethysmography, respiratory pattern, respectively. B and C, both arterial pressure and pulse oximetry plethysmography oscillate during the respiratory cycles, which is shown in D, due to the change in intrathoracic pressure, preload, and LV SV during mechanical ventilation. In B, the area arterial pressure wave under the curve is the LV SV. SVV (%) can be calculated with the equation (SV max – SV min) / SV mean. The arterial pressure wave peak is the SBP, and the trough is the DBP, PP is the difference between SBP and DBP. PPV (%) is calculated from 100 × (PP max – PP min) / ([PP max + PP min]/2) [121,122].
Figure 3 shows the dynamic parameter equations, which are crucial to understand how to interpret each parameter accurately, and for providers to judge the appropriateness to use each parameter in different physiological states or surgeries. For example, PVi may not be accurate in low perfusion states due to its use of perfusion index.
Figure 3.

Dynamic Parameters and Physiology Equations.
Pulse Pressure Variation (PPV) in Goal-Directed Fluid Therapy
PPV is a fluid responsiveness dynamic parameter described by Coyle et al. in 1983 [34]. PPV is calculated by measuring PP alterations during the respiratory cycle (Figure 2b) [35]. In general, patients with a PPV <12% are unlikely to benefit from further fluid therapy, whereas those with >12% are more likely to benefit from fluid resuscitation [36]. Compared to CVP, which requires a central venous catheter, PPV requires a minimally invasive or noninvasive monitor, commonly an arterial catheter. It is important to note that PPV does not indicate a patient’s fluid status or preload; rather, it is only an indicator of the patient’s position on the Frank-Starling curve [37].
PPV has been used to guide GDFT. For example, Malbouisson et al. showed that PPV-guided GDFT reduced postoperative complications such as respiratory, renal, and hepatic dysfunctions, and hospital length of stay, in high-risk patients undergoing open surgeries [38]. However, there have been small RCTs with negative clinical results on PPV-guided GDFT. For instance, Suzuki et al. found that PPV-guided GDFT did not significantly affect renal, hemodynamic, and metabolic variables in patients after they underwent cardiac surgery [39].
Moreover, PPV faces some limitations. To ensure accurate PPV measurement, the patient must be mechanically ventilated, the chest must be closed (an open chest will affect the interaction between the pericardium and mechanical ventilation), be in sinus rhythm, and intra-abdominal pressure must be within the normal range [33]. Other parameters that may affect PPV readings include extreme bradycardia or high respiratory rate, low tidal-volume ventilation (must be between 6 to 8 ml/kg), high positive end-expiratory pressure (PEEP) (PEEP should be between 0 and 5 cm H2O), low arterial compliance (high dose vasopressors, severe atherosclerosis), and RV or LV failure [32,33,40,41]. Also, if respiratory system compliance is ≤30 mL/cm H2O, such as in patients with ARDS, PPV will become less accurate [41,42].
Pleth Variability Index (PVi) in Goal-Directed Fluid Therapy
PVi is calculated from plethysmographic waveform amplitudes and PP derived from pulse oximetry or other devices. It was commercialized in 2007 [43]. This dynamic parameter has been shown to predict fluid responsiveness as accurate as Stroke Volume Variation [44], esophageal doppler [45], and PPV [46]. PVi also depends on the increased intrathoracic pressure interaction with the RV preload and the LV SV upon mechanical ventilation, which causes variation in the plethysmographic waveform amplitudes and area under the curve (Figure 2c). PVi is calculated by measuring perfusion index (PI) alterations during the respiratory cycle, which is described as the percentage of light absorbed as a result of arterial pulsation (AC) relative to total amount of light absorbed (DC). PVi is then calculated from the PI (Figure 4a-c) [48].
Figure 4.

PVi and PI calculations. In A, DC is the total amount of light absorbed and AC is the light absorbed as a result of arterial pulsation, which oscillates during respiration. B, PI (%) is calculated with the equation (AC/DC) × 100%. C, PVi (%) is then calculated from the PI with the equation [(PI max – PI min) / PI max] × 100% [121].
In a single-center RCT, Cesur et al. showed that in 70 ASA I and II patients, PVi-guided GDFT decreased the amount of fluids administered and the return of bowel function time [47]. Additionally, Patrice et al. demonstrated that PVi-guided GDFT decreases lactate level and fluid administration during major abdominal surgery [48]. Likewise, a study by Yu et al. found Pvi-guided GDFT decreases blood lactate level in the first hour of surgery and reduces fluid administration. However, the study found no changes in lactate level beyond the first hour, possibly due to its small sample size of 30 patients [49].
Currently, most GDFT studies using PVi are in abdominal surgeries. While there are great promises for this parameter, more studies must be done on other types of surgery to verify its use. Moreover, there is no definitive PVi cutoff in predicting fluid responsiveness, but most RCTs decided that it is around 13% to 14% [48,50]. Additionally, because PI is measured by pulse oximetry, nail coloring, skin coloring, and altered physiological states (such as methemoglobin) may change infrared light absorption leading to inaccurate calculations. Finally, because PVi is based on the same principle as PPV, both suffer the same limitations.
Stroke Volume Variation (SVV) in Goal-Directed Fluid Therapy
SVV is calculated from the difference between the maximum and minimum SV over the respiratory cycle and is caused by changes in RV preload due to alterations in intrathoracic pressure (Figure 2b). Patients with a SVV of <10% are unlikely to be fluid responsive, whereas those with SVV >15% are likely to benefit from fluid resuscitation [51].
SVV-guided GDFT has been shown in multiple single-center RCTs that it is an effective way to decrease postoperative complications in bowel, orthopedics, and neurosurgery [52-56]. For instance, Gottin et al. compared three methods of resuscitation in patients undergoing pancreatic surgery: liberal, restrictive, and SVV-guided GDFT. This study demonstrated that SVV-guided GDFT and restrictive fluid resuscitation decreased major surgical complications such as postoperative fistula, abdominal collection, and hemorrhage compared to liberal fluid resuscitation [57]. However, while most studies showed that SVV-guided GDFT improved postoperative outcomes, some studies showed the contrary. For example, Iwasaki et al. showed that SVV-guided GDFT hepato-biliary-pancreatic surgery patients had greater amount of fluids administered, and lower PaO2/FiO2 ratio on postoperative day one [58].
Interestingly, Wang et al. showed that in elective retroperitoneal tumor resections, patients who were resuscitated at SVV 9% has increased serum syndecan-1, interleukin-6, and tumor necrosis factor-α, as well as higher incidence of fever and blood transfusion when compared to patients resuscitated at SVV 14%. This suggests that increased fluid administration may enhance perioperative glycocalyx shedding leading to significant inflammatory responses [59].
Because SSV is based on the same principle as PPV, it also faces the same restriction as discussed above [41].
Aortic Blood Flow Peak Velocity Variation (ΔVpeak) in Goal-Directed Fluid Therapy
Because LV SV changes during different phases of mechanical ventilation, the aortic blood flow peak velocity will also vary. If the patient is at the plateau of the Frank-Starling relationship and thus fluid nonresponsive, such variations will be minimal. If the patient is fluid responsive, it will be vice versa. Marc et al. first described this parameter in 2001, where he reported that ΔVpeak of 12% has a sensitivity of 100% and a specificity of 89% to distinguish fluid responders from non-responders in adults [60].
ΔVpeak can be used to determine a patient’s fluid responsiveness in situations when PPV, SVV, or PVi cannot be measured accurately. This is especially true in pediatric and neonatal patients since they are ventilated by small tidal volumes, have higher arterial vascular compliance, and have higher chest wall and lung compliance. Therefore, in these patients, changes in intrathoracic pressure during mechanical ventilation may not cause the same circulatory changes as with adults. For example, Gan et al. demonstrated in a systemic review that ΔVpeak is the only dynamic or static variable that can predict fluid responsiveness in pediatric patients. PPV, SVV, and PVi did not predict fluid responsiveness in children [61].
Currently, there are no optimal cutoff points for ΔVpeak to assess fluid responsiveness. Furthermore, vasoactive drug effects on this parameter in the pediatric population are largely unknown [62]. However, this newer dynamic parameter holds many promises in pediatric resuscitation. A multicenter RCT is currently investigating ΔVpeak-guided GDFT on postoperative outcomes in pediatric patients undergoing elective or urgent major noncardiac surgery [63]. It will be interesting to see what this RCT shows and how ΔVpeak can further enhance pediatric surgery fluid optimization and postoperative outcomes.
Goal-Directed Fluid Therapy Monitoring Systems
Currently, there are many methods to monitor fluid responsiveness dynamic parameters in the perioperative setting [51]. Traditionally, the Swan–Ganz catheter has been used to measure CO, a fluid responsiveness static parameter, despite multiple studies showing Swan–Ganz catheters do not improve clinical outcomes [64]. Moreover, it is invasive and can lead to numerous complications such as thrombosis, pulmonary artery rupture, infection, and arrhythmia on insertion [51]. Therefore, other minimal or noninvasive hemodynamic monitoring systems have been developed [65,66]. In the section below, we will focus on common and popular monitoring systems which have been verified and used preoperatively for GDFT. A summary of the monitoring systems is shown in Table 2.
Flotrac™ for Goal-Directed Fluid Therapy
Flotrac™ (Edwards Lifesciences, Irvine, CA, USA) was first introduced in 2005 to be used with the EV1000 monitor or Vigileo monitor [67]. It uses a blood flow sensor that is attached to an arterial catheter. Hemodynamic parameters such as CO, SV, SVV, and systemic vascular resistance (SVR) are calculated every 20 seconds with a proprietary algorithm using pulse contour analysis. SV is derived from the equation: K × Pulsatility (standard deviation of the arterial pressure wave over 20 seconds), where K is a constant. K is derived from the sex, age, height and weight according to methods described by Langewouters et al. [68] and the skewness and kurtosis of the individual arterial waveform. K is recalculated automatically every minute based on the patient’s specific vascular compliance. Then, the CO is calculated by multiplying SV with pulse rate [69].
Flotrac™ does not need to be calibrated for use [67]. However, because the hemodynamic parameter calculations are heavily dependent on the constant, K, the software needs to recognize changes in vasodilation or vasoplegia to calculate an accurate CO.
Some studies have found that Flotrac™ is comparable to other hemodynamic monitoring systems. For example, Mclean et al. found that Flotrac/Vigileo™ is comparable to transthoracic doppler echocardiography when measuring CO [70]. Also, Cannesson et al. showed that in patients undergoing coronary artery bypass grafting, the CO estimated by Flotrac™ is comparable with PAC thermodilution [71]. However, many studies questioned its accuracy, even when it was updated to its newest software version: the fourth generation. While Flotrac™ is reasonably accurate in stable patients, in patients with low SVR, Flotrac™ does not provide accurate CO measurement when compared to invasive CO monitoring [67]. For instance, Murata et al. showed that in end-stage liver failure patients, fourth-generation Flotrac™ and PAC readings had poor agreement with each other during liver transplantation [72]. Moreover, Lin et al. found that fourth-generation Flotrac™ had a 61.82% and 51.80% error in estimating the CO before and after cardiopulmonary bypass, respectively. Therefore, found it unsuitable to be used during or after cardiopulmonary bypass [73].
Nonetheless, Flotrac™ remains popular and has been used in multiple RCTs to guide GDFT with good clinical outcomes [53,74]. For example, Yu et al. demonstrated that in major gynecologic oncology surgery patients, Flotrac™-guided GDFT decreased postoperative complications risk significantly (OR = 0.572), especially in surgical site infection risk (OR = 0.127). Furthermore, GDFT patients received significantly less fluid infusion than the control group [74].
While Flotrac™ is easy and convenient to use, many questions remain of its use in high-risk patients, especially in patients suffering from vasoplegia. In the future, newer software updates from the manufacturer may resolve such issues and allow it to better estimate hemodynamic parameters.
LidCO™ for Goal-Directed Fluid Therapy
LiDCO™plus (Masimo, Irvine, CA, US) must be calibrated by lithium dilution before being used. This calibration method boluses 0.5 to 1.0 ml of lithium chloride (0.15 mmol ml-1) through a central or peripheral venous line. Then, blood is aspirated through an arterial catheter at a constant rate of 4 ml min−1 with a disposable electrode selective for lithium. The change in electrode voltage is converted to plasma lithium concentration, and a lithium concentration vs time curve is plotted to calculate plasma flow. Blood flow is calculated with plasma flow divided by 1 – packed cell volume [51].
After calibration, it uses a propriety PulseCO™ algorithm, a pulse power algorithm, to calculate the CO. The algorithm uses the conservation of mass, rather than pulse contour, and assumes the net power change in a heartbeat between the input of a mass (SV) of blood minus the blood mass lost to the periphery during the beat has a linear relationship with net flow [75]. By doing so, LiDCO™ can also calculate the SV, SVR, SVV, oxygen delivery, and PPV.
LiDCO™plus has been validated and compared against other hemodynamic monitoring systems. For example, Mora et al. showed that LiDCO™plus is comparable to PAC thermodilution in patients with impaired LV SV after cardiac surgery [76]. The newer models of LiDCO™, such as the LiDCO™rapid and LiDCO™ LXi, are noninvasive and require no calibration. Instead, they use a two-finger cuff applied to the patient’s hand to measure the parameters. These newer models still use the same algorithm and have shown benefits in multiple RCTs [77,78]. More importantly, the OPTIMIZE trial used LiDCO™rapid-guided GDFT, which showed postoperative clinical benefits.
However, like Flotrac™, some studies have questioned LiDCO™rapid’s accuracy. For example, Asmaoto et al. examined Flotrac™ and LiDCO™rapid across a broad range of cardiac indexes (CI). Both monitors tended to underestimate CIs when the PAC measured CIs were relatively high [79]. LiDCO™rapid is a convenient and noninvasive option to guide fluid therapy, though there are unanswered questions about its utility in different physiological states. More studies on different types of surgery may help address some of these issues.
Masimo Radical 7 Pulse CO-Oximeter™ for Goal-Directed Fluid Therapy
Masimo Radical 7 Monitor (Masimo, Irvine, CA, US) can measure the PVi using a Masimo pulse oximeter, which can be attached to the ear, digits, or forehead [80]. This monitor does not need to be calibrated and is noninvasive. It is also the only commercially available monitor to measure PVi.
Multiple studies used Masimo pulse oximetry for GDFT to achieve improved postoperative outcomes. For instance, Saugel et al. showed that PVi-guided GDFT reduced ileus significantly and decreased fluid administrated in colorectal surgical patients [81]. Also, Collange et al. found that a PVi >9% before renal artery unclamping is an individual risk for delayed graft function in renal transplant patients [82]. However, the Optimization using the Pleth Variability Index (OPVI) trial, in which 447 ASA I and ASA II patients were randomized, showed that forehead measured Pvi-guided GDFT did not shorten hospital stay, or reduce postoperative complications such as AKI. This study, however, attributed these results to patients being of lower acuity [27].
Compared to other dynamic parameters, PVi is equivalent. For example, Coeckelenbergh et al. showed that in low- to intermediate-risk abdominal surgeries, patients who underwent PVi-guided GDFT or PPV-guided GDFT had no significant differences in hospital length of stay, postoperative outcomes, and amount of fluids administered [83]. In another study, Pişkin et al. showed that PVi and inferior vena cava distensibility index could predict fluid responsiveness comparably in intensive care patients [84].
However, PVi may be inaccurate in specific patient populations. Konur et al. found that in liver transplant patients, PVi cannot distinguish fluid responders from non-responders. PVi value was similar at baseline between responders and non-responders in the dissection and anhepatic phase. Only SVV measured by the PiCCO™ monitoring system was reliable [85]. Likewise, Le Guen et al. showed that PVi does not respond to fluid challenges and had poor agreement with esophageal doppler measurements in renal transplant patients [86].
Because PVi measurements require adequate perfusion, a change in blood flow may affect its reading. Currently, Masimo Radical 7 Pulse CO-Oximeter™ cannot determine if a decrease in blood flow is due to a depressed cardiovascular system or impaired blood flow to the tissue. Additionally, any physiological or pathological influences on the peripheral vascular flow, such as in patients with severe Raynaud’s phenomenon or with peripheral vascular disease, may affect PVi readings [87]. Thus, PVi should be used and interpreted cautiously.
ClearSight™ for Goal-Directed Fluid Therapy
ClearSight™ (Edwards Lifesciences, Irvine, CA, USA) is a noninvasive monitor which uses a finger cuff to estimate CO, SV, SVV, SVR, and mean arterial pressure (MAP). It was introduced in 2007 as Nexfin™. The finger cuff inflates and deflates to keep the diameter of finger arteries constant throughout the cardiac cycle. From the finger pressure waveform, it calculates the brachial pressure waveform using an algorithm. Then, it uses the pulse contour method to estimate CO [88].
Conflicting studies have shown that ClearSight™ may or may not be comparable to other invasive or minimally invasive hemodynamic monitoring systems. For example, Wang et al. showed that ClearSight™ is comparable to PAC thermodilution in estimating CO in cardiac surgery patients [89]. However, while Tanioku et al. found that ClearSight™ was interchangeable with arterial catheters in measuring MAP, it had significant biases when measuring SBP and DBP in cardiovascular surgeries [90]. Moreover, Kanazawa et al. demonstrated that ClearSight™ was inaccurate in estimating CI in patients with reduced cardiac ejection fraction (<55%) when compared to PAC thermodilution. However, it is accurate in measuring MAP [91].
Some studies also found that ClearSight™-guided GDFT has no postoperative benefits. Stens et al. showed that using ClearSight™ calculated CI, PPV and MAP for GDFT guidance had no impact on postoperative complications [92]. Furthermore, Fischer et al. found that in low-risk colorectal patients, using ClearSight™-guided GDFT does not affect hospital length of stay, postoperative mortality, and the total number of complications [93]. Similarly, Davies et al. found that ClearSight™-guided GDFT offers no postoperative complication benefits in high-risk patients undergoing hip fracture repair [94]. Given these questionable study results, this monitoring system needs to be studied more in multicenter RCTs to verify its benefit in GDFT.
PiCCO™ for Goal-Directed Fluid Therapy
PiCCO™ (Pulsion Medical System, Munich, Germany) uses the transpulmonary thermodilution technique for CO estimations. To calibrate the monitor, it requires a bolus of cold saline in a central venous catheter, then a thermo-sensor tip arterial catheter senses the decrease in blood temperature. The difference between this system and PAC transpulmonary thermodilution is that the cold solution is bolused into a central vein, not in the right atria. Therefore, the temperature change detection is at a peripheral artery rather than the pulmonary artery. Uniquely, this monitoring system can also measure global end-diastolic volume [95], global ejection fraction, intrathoracic blood volume, and extravascular lung water [96].
Goedje et al. found that PiCCO™ had a comparable and robust correlation with PAC thermodilution with a mean bias of 0.07-liter min-1 (2 SD 1.4-liter min-1) in post-cardiac surgery patients. These patients had various CO (ranging from 3.0 to 11.8 liter min-1) and SVR (ranging from 252 to 2434 dyn s cm-5) [97]. Moreover, it has been shown to improve postoperative outcome when used to guide GDFT. For instance, Jing et al. demonstrated that PiCCO™-guided GDFT decreased volume infusion, hospital stay length, and time needed for ambulation [98]. However, in emergency surgeries, PiCCO™-guided GDFT increased major complications (95% vs 40% in the control group) and did not decrease in-hospital mortality [99].
While PiCCO™ offers a less invasive approach than PAC, it still requires a central venous catheter and arterial catheter, which may be impractical in many surgeries and can only be used in high-risk patients. Therefore, this method continues to have many limitations.
Esophageal Doppler for Goal-Directed Fluid Therapy
Esophageal Doppler (ED) is an ultrasound-based technique introduced in the 1970s, which allows aortic blood flow measurements in the descending thoracic aorta to calculate CO and SV [100]. It is the only minimally invasive CO monitor evaluated and endorsed by the United States Agency for Healthcare Research and Quality and the United Kingdom Centre for evidence-based purchasing [101].
The ED is a 6-mm probe positioned at the distal esophagus to measure blood flow velocity in the descending thoracic aorta. The blood flow velocity waveform also can be used to measure flow time, which is the time from the start of the waveform upstroke to return to baseline. When corrected for HR, flow time is found to be a sensitive measure of LV filling, thus an accurate RV preload measurement [102].
ED is comparable to PAC thermodilution in measuring intensive care patients’ CO [103]. Studies also showed that ED produced similar clinical results as Flotrac™-guided GDFT [104] and NICOM-guided GDFT [105]. Furthermore, a systemic review by ECRI Evidence-based Practice Center, an independent federally certified patient safety organization by the US Department of Health and Human Services, has found that there is high quality evidence that ED reduces postoperative complications and hospital length of stay [106]. Due to its accuracy and longevity, ED had become the noninvasive fluid status monitor of choice. Both the RELIEF and FEDORA trials used ED-guided GDFT.
Despite much evidence supporting ED’s use in GDFT, some limitations exist. First, it requires some skills; thus, the user must be trained. Secondly, it cannot be used in esophageal surgeries, patients with esophageal anatomical anomalies, or with recent esophagus surgeries. Thirdly, liver cirrhosis patients may have esophageal varices and ED can induce bleeding. Finally, the doppler signal can be poor due to aorta or user issues.
Echocardiogram (ECHO) for Goal-Directed Fluid Therapy
Transesophageal (TEE) or Transthoracic Echocardiogram (TTE) are frequently used to guide fluid therapy in high-risk cardiothoracic and liver transplant surgeries. They are ultrasound imaging techniques that can visualize the heart or the aorta directly [107]. This direct visualization allows multiple hemodynamic parameters to be calculated or measured in real-time. For example, the LV outflow tract velocity time integral (VTI) is a measurement by ECHO of how far blood travels during the flow period. It is a LV systolic function surrogate, which can be used to calculate the SV and then the CO, by multiplying with HR [108]. Moreover, TEE can estimate the preload using the LV end-diastolic area [109]. These visualized changes in preload can detect even minor volume deficits. TEE and TTE can also detect inferior vena cava diameter variations (ΔIVCD) during tidal respiration in mechanically ventilated patients, which correlates with SVV [110]. ΔIVCD can also be used to calculate the caval index (Figure 3); a caval index <50% is strongly associated with a CVP of <8 mmHg [111].
While TEE and TTE are well-established monitors for fluid resuscitation intraoperatively and has shown benefits in intensive care patients, it lacks studies on postoperative outcomes in low- and moderate-risk surgeries. Furthermore, TEE has limitations. It cannot be used in patients with previous esophageal surgeries and cannot be used in esophageal surgeries. Probe insertion can lead to bleeding in cirrhotic patients with esophageal varices. Also, both TTE and TEE probes must be positioned by a trained professional to interpret the images. Finally, the TEE probe cannot be used in awake patients.
Currently, TEE-guided GDFT is being investigated in a multicenter RCT for pediatric surgery postoperative outcomes [112]. It will be interesting to see how it will impact pediatric resuscitation.
Conclusion
In the last 20 years, there has been much advance in noninvasive detection of fluid status perioperatively, as an alternative to using PAC thermodilution. Each monitoring system uses different physiological principles and offers various pros and cons. Furthermore, these systems use different algorithms and methods to calculate dynamic parameters. Because of these different calculations, different monitors can display different values for the same dynamic parameter. As such, a clinician should consider the type of surgery being done, and the current evidence for GDFT-guided by that monitoring system and dynamic parameter. Moreover, a clinician should understand and be familiar with how dynamic parameters are calculated, and how they are derived from the monitoring systems.
Dynamic parameters are all based on the physiological principles of mechanical ventilation, intra-thoracic pressure, and LV SV changes. Thus, they have the same limitations. To ensure accurate measurement, the patient must be: 1) Mechanically ventilated, 2) Chest must be closed, 3) In sinus rhythm, and 4) Intra-abdominal pressure must be in the normal range. In addition, low arterial compliance and respiratory system compliance ≤30 mL/cm H2O can decrease the accuracy of parameters [42,43]. However, these factors may be compensated by the monitoring systems’ algorithm.
The selection of dynamic parameters for GDFT guidance is also affected by the surgery itself. For example, PVi has been shown to be unreliable in predicting fluid responsiveness in cardiac surgery patients when compared to PPV and SVV [113]. Even if the dynamic parameter is selected carefully, it has been demonstrated that few patients fit all the criteria for accurate dynamic parameter measurements in both perioperative and intensive care settings [40,114]. For example, Maguire et al. found that only 39% of surgical patients met the criteria for accurate noninvasive plethysmographic waveform variations monitoring [40]. Therefore, suggests that many providers may not be aware of all the requirements and surgical nuances for using dynamic parameters, leading to false readings and wrong interpretations.
Currently the American Society of Anesthesiologists nor other international medical societies endorse the use of any hemodynamic monitoring systems or dynamic parameters to guide GDFT. Furthermore, there are no GDFT clinical guidelines due to ongoing debates of its uses and benefits. However, there is strong evidence that esophageal doppler, as endorsed by the United States Agency for Healthcare Research and Quality and the United Kingdom Centre for evidence-based purchasing, can improve postoperative outcomes [101].
Outlook
While GDFT has been more prevalent than in previous decades, there continues to be slow adaptation of this fluid regimen, even though multiple studies have reported that GDFT offers postoperative benefits and is cost-effective. In a survey of anesthesiologists, only 35% reported they “always” use GDFT in the United States. Worse yet, only 15% and 10% of the anesthesiologist in the United Kingdom and Australia/New Zealand reported they “always” use GDFT respectively. The most common reason was the lack of monitoring tools availability, followed by a lack of experience with instruments [115].
With more RCTs, hopefully, there will be a change in attitude towards using GDFT and purchasing hemodynamic monitoring systems. It will be exciting to follow the current global multicenter RCT, the OPTIMISE II trial, which launched in January 2017. With over 30 participating centers in multiple countries, it has enrolled 2,502 patients undergoing major elective gastrointestinal surgery. This study will be the largest GDFT trial to date and will be using ClearSight™ or Flotract™ as hemodynamic monitors, with SVV as the dynamic parameter. Primary outcomes will be 180 day mortality, 30-day AKI rate, and acute cardiac event within 24 hours and 30 days [116].
As technology advances, perioperative hemodynamic monitors have also become more non-invasive. One exciting technology is the wireless and wearable doppler which may be comparable to TEE. For example, Kenny et al. showed that a wearable wireless carotid doppler at the common carotid artery is equivalent to TEE during coronary bypass surgeries; it can accurately detect the common carotid artery VTI, and significant changes in SV and aortic VTI after a straight leg raise test [117,118]. Wang et al. also described a wearable and flexible ultrasound doppler device similar to an electrocardiogram lead which can monitoring real time blood flow velocities in human arteries [119]. These new technologies and devices can circumvent the minimally invasive or invasive hemodynamic monitor systems’ limitations.
Another exciting progress is the increasing use of artificial intelligence, machine learning and big data to solve hemodynamic problems. Hatib et al. described the hypotension prediction index, which is developed by machine learning from the arterial waveform of 13,000 past hypotensive events and 12,000 non-hypotensive events. HPI can predict hypotension 15 minutes before the actual event occurs [120]. In the future, a new hemodynamic algorithm may go beyond PPV or SVV to allow patient fluid resuscitation before hypotension happens.
Glossary
- OPTIMIZE
Optimization of Cardiovascular Management to Improve Surgical Outcome
- ERAS
Enhanced recovery after surgery protocols
- GDFT
goal-directed fluid therapy
- PPV
pulse pressure variation
- PP
pulse pressure
- SBP
systolic blood pressure
- DBP
diastolic blood pressure
- SVV
stroke volume variation
- CVP
central venous pressure
- ΔVpeak
aortic blood flow peak velocity variation
- PPV
pulse pressure variation
- SVV
stroke volume variation
- Pvi
pleth variability index
- RCT
randomized clinical trials
- LV
left ventricular
- SV
stroke volume
- RV
right ventricular
- PAC
pulmonary artery catheter
- PP
pulse pressure
- PEEP
positive end-expiratory pressure
- CO
cardiac output
- ECHO
echocardiography
- OPVI
Optimization Using the Pleth Variability Index
- ED
esophageal doppler
- TEE
transesophageal echocardiogram
- TTE
transthoracic echocardiogram
- VTI
velocity time integral
- IV
intravenous
- RELIEF
Restrictive versus Liberal Fluid Therapy in Major Abdominal Surgery
- AUC
area under the curve
- CI
cardiac index
- ΔIVCD
inferior vena cava diameter variations
Author Contributions
CFK conceived the idea and wrote the manuscript, JDS provided substantial comments and edits to this manuscript.
References
- Moghadamyeghaneh Z, Phelan MJ, Carmichael JC, Mills SD, Pigazzi A, Nguyen NT, et al. Preoperative dehydration increases risk of postoperative acute renal failure in colon and rectal surgery. J Gastrointest Surg. 2014. Dec;18(12):2178–85. 10.1007/s11605-014-2661-7 [DOI] [PubMed] [Google Scholar]
- Zanetti M, De Colle P, Omiciuolo C, Ratti C, Gortan Cappellari G, Barazzoni R, et al. Postoperative Dehydration Is Associated with Frailty and Decreased Survival in Older Patients with Hip Fracture. Nutrients. 2022. Feb;14(4):820. 10.3390/nu14040820 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Myles PS, Bellomo R, Corcoran T, Forbes A, Peyton P, Story D, et al. Australian and New Zealand College of Anaesthetists Clinical Trials Network and the Australian and New Zealand Intensive Care Society Clinical Trials Group. Restrictive versus Liberal Fluid Therapy for Major Abdominal Surgery. N Engl J Med. 2018. Jun;378(24):2263–74. 10.1056/NEJMoa1801601 [DOI] [PubMed] [Google Scholar]
- Arieff AI. Fatal postoperative pulmonary edema: pathogenesis and literature review. Chest. 1999. May;115(5):1371–7. 10.1378/chest.115.5.1371 [DOI] [PubMed] [Google Scholar]
- Blank RS, Hucklenbruch C, Gurka KK, Scalzo DC, Wang XQ, Jones DR, et al. Intraoperative factors and the risk of respiratory complications after pneumonectomy. Ann Thorac Surg. 2011. Oct;92(4):1188–94. 10.1016/j.athoracsur.2011.06.022 [DOI] [PubMed] [Google Scholar]
- Kang D, Yoo KY. Fluid management in perioperative and critically ill patients. Acute Crit Care. 2019. Nov;34(4):235–45. 10.4266/acc.2019.00717 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Asrani VM, Brown A, Bissett I, Windsor JA. Impact of Intravenous Fluids and Enteral Nutrition on the Severity of Gastrointestinal Dysfunction: A Systematic Review and Meta-analysis. J Crit Care Med (Targu Mures). 2020. Jan;6(1):5–24. 10.2478/jccm-2020-0009 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chappell D, Bruegger D, Potzel J, Jacob M, Brettner F, Vogeser M, et al. Hypervolemia increases release of atrial natriuretic peptide and shedding of the endothelial glycocalyx. Crit Care. 2014. Oct;18(5):538. 10.1186/s13054-014-0538-5 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Holte K, Klarskov B, Christensen DS, Lund C, Nielsen KG, Bie P, et al. Liberal versus restrictive fluid administration to improve recovery after laparoscopic cholecystectomy: a randomized, double-blind study. Ann Surg. 2004. Nov;240(5):892–9. 10.1097/01.sla.0000143269.96649.3b [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bundgaard-Nielsen M, Secher NH, Kehlet H. ‘Liberal’ vs. ‘restrictive’ perioperative fluid therapy—a critical assessment of the evidence. Acta Anaesthesiol Scand. 2009. Aug;53(7):843–51. 10.1111/j.1399-6576.2009.02029.x [DOI] [PubMed] [Google Scholar]
- Nisanevich V, Felsenstein I, Almogy G, Weissman C, Einav S, Matot I. Effect of intraoperative fluid management on outcome after intraabdominal surgery. Anesthesiology. 2005. Jul;103(1):25–32. 10.1097/00000542-200507000-00008 [DOI] [PubMed] [Google Scholar]
- Lobo DN, Bostock KA, Neal KR, Perkins AC, Rowlands BJ, Allison SP. Effect of salt and water balance on recovery of gastrointestinal function after elective colonic resection: a randomised controlled trial. Lancet. 2002. May;359(9320):1812–8. 10.1016/S0140-6736(02)08711-1 [DOI] [PubMed] [Google Scholar]
- Hendrix RJ, Damle A, Williams C, Harris A, Spanakis S, Lambert DH, et al. Restrictive Intraoperative Fluid Therapy is Associated with Decreased Morbidity and Length of Stay Following Hyperthermic Intraperitoneal Chemoperfusion. Ann Surg Oncol. 2019. Feb;26(2):490–6. 10.1245/s10434-018-07092-y [DOI] [PubMed] [Google Scholar]
- Maheshwari K, Sessler DI. Goal-directed Therapy: Why Benefit Remains Uncertain. Anesthesiology. 2020. Jul;133(1):5–7. 10.1097/ALN.0000000000003337 [DOI] [PubMed] [Google Scholar]
- Dalfino L, Giglio MT, Puntillo F, Marucci M, Brienza N. Haemodynamic goal-directed therapy and postoperative infections: earlier is better. A systematic review and meta-analysis. Crit Care. 2011. Jun;15(3):R154. 10.1186/cc10284 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Giglio M, Dalfino L, Puntillo F, Rubino G, Marucci M, Brienza N. Haemodynamic goal-directed therapy in cardiac and vascular surgery. A systematic review and meta-analysis. Interact Cardiovasc Thorac Surg. 2012. Nov;15(5):878–87. 10.1093/icvts/ivs323 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Corcoran T, Rhodes JE, Clarke S, Myles PS, Ho KM. Perioperative fluid management strategies in major surgery: a stratified meta-analysis. Anesth Analg. 2012. Mar;114(3):640–51. 10.1213/ANE.0b013e318240d6eb [DOI] [PubMed] [Google Scholar]
- Prowle JR, Chua HR, Bagshaw SM, Bellomo R. Clinical review: volume of fluid resuscitation and the incidence of acute kidney injury - a systematic review. Crit Care. 2012. Aug;16(4):230. 10.1186/cc11345 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lobo DN, Stanga Z, Aloysius MM, Wicks C, Nunes QM, Ingram KL, et al. Effect of volume loading with 1 liter intravenous infusions of 0.9% saline, 4% succinylated gelatine (Gelofusine) and 6% hydroxyethyl starch (Voluven) on blood volume and endocrine responses: a randomized, three-way crossover study in healthy volunteers. Crit Care Med. 2010. Feb;38(2):464–70. 10.1097/CCM.0b013e3181bc80f1 [DOI] [PubMed] [Google Scholar]
- Pearse RM, Harrison DA, MacDonald N, Gillies MA, Blunt M, Ackland G, et al. OPTIMISE Study Group. Effect of a perioperative, cardiac output-guided hemodynamic therapy algorithm on outcomes following major gastrointestinal surgery: a randomized clinical trial and systematic review. JAMA. 2014. Jun;311(21):2181–90. 10.1001/jama.2014.5305 [DOI] [PubMed] [Google Scholar]
- Gillies MA, Shah AS, Mullenheim J, Tricklebank S, Owen T, Antonelli J, et al. Perioperative myocardial injury in patients receiving cardiac output-guided haemodynamic therapy: a substudy of the OPTIMISE Trial. Br J Anaesth. 2015. Aug;115(2):227–33. 10.1093/bja/aev137 [DOI] [PubMed] [Google Scholar]
- Sadique Z, Harrison DA, Grieve R, Rowan KM, Pearse RM, OPTIMISE study group. Cost-effectiveness of a cardiac output-guided haemodynamic therapy algorithm in high-risk patients undergoing major gastrointestinal surgery. Perioper Med (Lond). 2015. Dec;4(1):13. 10.1186/s13741-015-0024-x [DOI] [PMC free article] [PubMed] [Google Scholar]
- Calvo-Vecino JM, Ripollés-Melchor J, Mythen MG, Casans-Francés R, Balik A, Artacho JP, et al. FEDORA Trial Investigators Group. Effect of goal-directed haemodynamic therapy on postoperative complications in low-moderate risk surgical patients: a multicentre randomised controlled trial (FEDORA trial). Br J Anaesth. 2018. Apr;120(4):734–44. 10.1016/j.bja.2017.12.018 [DOI] [PubMed] [Google Scholar]
- Gómez-Izquierdo JC, Trainito A, Mirzakandov D, Stein BL, Liberman S, Charlebois P, et al. Goal-directed Fluid Therapy Does Not Reduce Primary Postoperative Ileus after Elective Laparoscopic Colorectal Surgery: A Randomized Controlled Trial. Anesthesiology. 2017. Jul;127(1):36–49. 10.1097/ALN.0000000000001663 [DOI] [PubMed] [Google Scholar]
- Challand C, Struthers R, Sneyd JR, Erasmus PD, Mellor N, Hosie KB, et al. Randomized controlled trial of intraoperative goal-directed fluid therapy in aerobically fit and unfit patients having major colorectal surgery. Br J Anaesth. 2012. Jan;108(1):53–62. 10.1093/bja/aer273 [DOI] [PubMed] [Google Scholar]
- Bisgaard J, Gilsaa T, Rønholm E, Toft P. Optimising stroke volume and oxygen delivery in abdominal aortic surgery: a randomised controlled trial. Acta Anaesthesiol Scand. 2013. Feb;57(2):178–88. 10.1111/j.1399-6576.2012.02756.x [DOI] [PubMed] [Google Scholar]
- Fischer MO, Lemoine S, Tavernier B, Bouchakour CE, Colas V, Houard M, et al. Optimization using the Pleth Variability Index (OPVI) Trial Group. Individualized Fluid Management Using the Pleth Variability Index: A Randomized Clinical Trial. Anesthesiology. 2020. Jul;133(1):31–40. 10.1097/ALN.0000000000003260 [DOI] [PubMed] [Google Scholar]
- De Backer D, Vincent JL. Should we measure the central venous pressure to guide fluid management? Ten answers to 10 questions. Crit Care. 2018. Feb;22(1):43. 10.1186/s13054-018-1959-3 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Jozwiak M, Monnet X, Teboul JL. Prediction of fluid responsiveness in ventilated patients. Ann Transl Med. 2018. Sep;6(18):352. 10.21037/atm.2018.05.03 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Goyal VK, Gupta P, Baj B, Garg VK. A randomized comparison between pulse pressure variation and central venous pressure in patients undergoing renal transplantation. J Anaesthesiol Clin Pharmacol. 2021;37(4):628–32. 10.4103/joacp.JOACP_23_20 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sundaram SC, Salins SR, Kumar AN, Korula G. Intra-Operative Fluid Management in Adult Neurosurgical Patients Undergoing Intracranial Tumour Surgery: Randomised Control Trial Comparing Pulse Pressure Variance (PPV) and Central Venous Pressure (CVP). J Clin Diagn Res. 2016. May;10(5):UC01–05. 10.7860/JCDR/2016/18377.7850 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Monnet X, Marik PE, Teboul JL. Prediction of fluid responsiveness: an update. Ann Intensive Care. 2016. Dec;6(1):111. 10.1186/s13613-016-0216-7 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Piccioni F, Bernasconi F, Tramontano GT, Langer M. A systematic review of pulse pressure variation and stroke volume variation to predict fluid responsiveness during cardiac and thoracic surgery. J Clin Monit Comput. 2017. Aug;31(4):677–84. 10.1007/s10877-016-9898-5 [DOI] [PubMed] [Google Scholar]
- Coyle J, Teplick R, Long M, Davison J. Respiratory variations in systemic arterial pressure as an indicator of volume status. Anesthesiology. 1983;59(3):A53. [Google Scholar]
- Lee JH, Jeon Y, Bahk JH, Gil NS, Kim KB, Hong DM, et al. Pulse-pressure variation predicts fluid responsiveness during heart displacement for off-pump coronary artery bypass surgery. J Cardiothorac Vasc Anesth. 2011. Dec;25(6):1056–62. 10.1053/j.jvca.2011.07.013 [DOI] [PubMed] [Google Scholar]
- Yang X, Du B. Does pulse pressure variation predict fluid responsiveness in critically ill patients? A systematic review and meta-analysis. Crit Care. 2014. Nov;18(6):650. 10.1186/s13054-014-0650-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Michard F, Lopes MR, Auler JO Jr. Pulse pressure variation: beyond the fluid management of patients with shock. Crit Care. 2007;11(3):131. 10.1186/cc5905 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Malbouisson LM, Silva JM Jr, Carmona MJ, Lopes MR, Assunção MS, Valiatti JL, et al. A pragmatic multi-center trial of goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery. BMC Anesthesiol. 2017. May;17(1):70. 10.1186/s12871-017-0356-9 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Suzuki S, Woinarski NC, Lipcsey M, Candal CL, Schneider AG, Glassford NJ, et al. Pulse pressure variation-guided fluid therapy after cardiac surgery: a pilot before-and-after trial. J Crit Care. 2014. Dec;29(6):992–6. 10.1016/j.jcrc.2014.07.032 [DOI] [PubMed] [Google Scholar]
- Maguire S, Rinehart J, Vakharia S, Cannesson M. Technical communication: respiratory variation in pulse pressure and plethysmographic waveforms: intraoperative applicability in a North American academic center. Anesth Analg. 2011. Jan;112(1):94–6. 10.1213/ANE.0b013e318200366b [DOI] [PubMed] [Google Scholar]
- Myatra SN, Monnet X, Teboul JL. Use of ‘tidal volume challenge’ to improve the reliability of pulse pressure variation. Crit Care. 2017. Mar;21(1):60. 10.1186/s13054-017-1637-x [DOI] [PMC free article] [PubMed] [Google Scholar]
- Monnet X, Bleibtreu A, Ferré A, Dres M, Gharbi R, Richard C, et al. Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance. Crit Care Med. 2012. Jan;40(1):152–7. 10.1097/CCM.0b013e31822f08d7 [DOI] [PubMed] [Google Scholar]
- Nilsson LM. Respiration signals from photoplethysmography. Anesth Analg. 2013. Oct;117(4):859–65. 10.1213/ANE.0b013e31828098b2 [DOI] [PubMed] [Google Scholar]
- Zimmermann M, Feibicke T, Keyl C, Prasser C, Moritz S, Graf BM, et al. Accuracy of stroke volume variation compared with pleth variability index to predict fluid responsiveness in mechanically ventilated patients undergoing major surgery. Eur J Anaesthesiol. 2010. Jun;27(6):555–61. 10.1097/EJA.0b013e328335fbd1 [DOI] [PubMed] [Google Scholar]
- Bahlmann H, Hahn RG, Nilsson L. Pleth variability index or stroke volume optimization during open abdominal surgery: a randomized controlled trial. BMC Anesthesiol. 2018. Aug;18(1):115. 10.1186/s12871-018-0579-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kim DH, Shin S, Kim JY, Kim SH, Jo M, Choi YS. Pulse pressure variation and pleth variability index as predictors of fluid responsiveness in patients undergoing spinal surgery in the prone position. Ther Clin Risk Manag. 2018. Jul;14:1175–83. 10.2147/TCRM.S170395 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Cesur S, Çardaközü T, Kuş A, Türkyılmaz N, Yavuz Ö. Comparison of conventional fluid management with PVI-based goal-directed fluid management in elective colorectal surgery. J Clin Monit Comput. 2019. Apr;33(2):249–57. 10.1007/s10877-018-0163-y [DOI] [PMC free article] [PubMed] [Google Scholar]
- Forget P, Lois F, de Kock M. Goal-directed fluid management based on the pulse oximeter-derived pleth variability index reduces lactate levels and improves fluid management. Anesth Analg. 2010. Oct;111(4):910–4. 10.1213/ANE.0b013e3181eb624f [DOI] [PubMed] [Google Scholar]
- Yu Y, Dong J, Xu Z, Shen H, Zheng J. Pleth variability index-directed fluid management in abdominal surgery under combined general and epidural anesthesia. J Clin Monit Comput. 2015. Feb;29(1):47–52. 10.1007/s10877-014-9567-5 [DOI] [PubMed] [Google Scholar]
- Demirel İ, Bolat E, Altun AY, Özdemir M, Beştaş A. Efficacy of Goal-Directed Fluid Therapy via Pleth Variability Index During Laparoscopic Roux-en-Y Gastric Bypass Surgery in Morbidly Obese Patients. Obes Surg. 2018. Feb;28(2):358–63. 10.1007/s11695-017-2840-1 [DOI] [PubMed] [Google Scholar]
- Drummond KE, Murphy E. Minimally invasive cardiac output monitors. Contin Educ Anaesth Crit Care Pain. 2011;12(1):5–10. 10.1093/bjaceaccp/mkr044 [DOI] [Google Scholar]
- Ramsingh DS, Sanghvi C, Gamboa J, Cannesson M, Applegate RL 2nd. Outcome impact of goal directed fluid therapy during high risk abdominal surgery in low to moderate risk patients: a randomized controlled trial. J Clin Monit Comput. 2013. Jun;27(3):249–57. 10.1007/s10877-012-9422-5 [DOI] [PubMed] [Google Scholar]
- Negrini D, Graaf J, Ihsan M, Gabriela Correia A, Freitas K, Bravo JA, et al. The clinical impact of the systolic volume variation guided intraoperative fluid administration regimen on surgical outcomes after pancreaticoduodenectomy: a retrospective cohort study. Braz J Anesthesiol. 2022;72(6):729–35. 10.1016/j.bjane.2022.06.008 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lee KY, Yoo YC, Cho JS, Lee W, Kim JY, Kim MH. The Effect of Intraoperative Fluid Management According to Stroke Volume Variation on Postoperative Bowel Function Recovery in Colorectal Cancer Surgery. J Clin Med. 2021. Apr;10(9):1857. 10.3390/jcm10091857 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Benes J, Chytra I, Altmann P, Hluchy M, Kasal E, Svitak R, et al. Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study. Crit Care. 2010;14(3):R118. 10.1186/cc9070 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wu CY, Lin YS, Tseng HM, Cheng HL, Lee TS, Lin PL, et al. Comparison of two stroke volume variation-based goal-directed fluid therapies for supratentorial brain tumour resection: a randomized controlled trial. Br J Anaesth. 2017. Nov;119(5):934–42. 10.1093/bja/aex189 [DOI] [PubMed] [Google Scholar]
- Gottin L, Martini A, Menestrina N, Schweiger V, Malleo G, Donadello K, et al. Perioperative Fluid Administration in Pancreatic Surgery: a Comparison of Three Regimens. J Gastrointest Surg. 2020. Mar;24(3):569–77. 10.1007/s11605-019-04166-4 [DOI] [PubMed] [Google Scholar]
- Iwasaki Y, Ono Y, Inokuchi R, Ishida T, Kumada Y, Shinohara K. Intraoperative fluid management in hepato-biliary-pancreatic operation using stroke volume variation monitoring: A single-center, open-label, randomized pilot study. Medicine (Baltimore). 2020. Dec;99(50):e23617. 10.1097/MD.0000000000023617 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wang X, Duan Y, Gao Z, Gu J. Effect of Goal-directed Fluid Therapy on the Shedding of the Glycocalyx Layer in Retroperitoneal Tumour Resection. J Coll Physicians Surg Pak. 2021. Oct;31(10):1179–85. 10.29271/jcpsp.2021.10.1179 [DOI] [PubMed] [Google Scholar]
- Feissel M, Michard F, Mangin I, Ruyer O, Faller JP, Teboul JL. Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest. 2001. Mar;119(3):867–73. 10.1378/chest.119.3.867 [DOI] [PubMed] [Google Scholar]
- Gan H, Cannesson M, Chandler JR, Ansermino JM. Predicting fluid responsiveness in children: a systematic review. Anesth Analg. 2013. Dec;117(6):1380–92. 10.1213/ANE.0b013e3182a9557e [DOI] [PubMed] [Google Scholar]
- Desgranges FP, Desebbe O, Pereira de Souza Neto E, Raphael D, Chassard D. Respiratory variation in aortic blood flow peak velocity to predict fluid responsiveness in mechanically ventilated children: a systematic review and meta-analysis. Paediatr Anaesth. 2016. Jan;26(1):37–47. 10.1111/pan.12803 [DOI] [PubMed] [Google Scholar]
- Kumba C. Goal directed fluid and hemodynamic therapy and postoperative outcomes in children: Value of trans-thoracic echocardiographic aortic blood flow peak velocity variation: A multicentre randomized controlled trial protocol. Adv Pediatr Res. 2020;7:1–6. [Google Scholar]
- Chatterjee K. The Swan-Ganz catheters: past, present, and future. A viewpoint. Circulation. 2009. Jan;119(1):147–52. 10.1161/CIRCULATIONAHA.108.811141 [DOI] [PubMed] [Google Scholar]
- Bodys-Pełka A, Kusztal M, Boszko M, Główczyńska R, Grabowski M. Non-Invasive Continuous Measurement of Haemodynamic Parameters-Clinical Utility. J Clin Med. 2021. Oct;10(21):4929. 10.3390/jcm10214929 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Legrand G, Ruscio L, Benhamou D, Pelletier-Fleury N. Goal-Directed Fluid Therapy Guided by Cardiac Monitoring During High-Risk Abdominal Surgery in Adult Patients: Cost-Effectiveness Analysis of Esophageal Doppler and Arterial Pulse Pressure Waveform Analysis. Value Health. 2015. Jul;18(5):605–13. 10.1016/j.jval.2015.04.005 [DOI] [PubMed] [Google Scholar]
- Argueta E, Berdine G, Pena C, Nugent KM. FloTrac® monitoring system: what are its uses in critically ill medical patients? Am J Med Sci. 2015. Apr;349(4):352–6. 10.1097/MAJ.0000000000000393 [DOI] [PubMed] [Google Scholar]
- Langewouters GJ, Wesseling KH, Goedhard WJ. The pressure dependent dynamic elasticity of 35 thoracic and 16 abdominal human aortas in vitro described by a five component model. J Biomech. 1985;18(8):613–20. 10.1016/0021-9290(85)90015-6 [DOI] [PubMed] [Google Scholar]
- Education EC. Quick Guide to Cardiopulmonary Care. 4th ed. 2018. [Google Scholar]
- McLean AS, Huang SJ, Kot M, Rajamani A, Hoyling L. Comparison of cardiac output measurements in critically ill patients: FloTrac/Vigileo vs transthoracic Doppler echocardiography. Anaesth Intensive Care. 2011. Jul;39(4):590–8. 10.1177/0310057X1103900409 [DOI] [PubMed] [Google Scholar]
- Cannesson M, Attof Y, Rosamel P, Joseph P, Bastien O, Lehot JJ. Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements. Eur J Anaesthesiol. 2007. Oct;24(10):832–9. 10.1017/S0265021507001056 [DOI] [PubMed] [Google Scholar]
- Murata Y, Imai T, Takeda C, Mizota T, Kawamoto S. Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation. Sci Rep. 2022. Jul;12(1):11198. 10.1038/s41598-022-14988-z [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lin SY, Chou AH, Tsai YF, Chang SW, Yang MW, Ting PC, et al. Evaluation of the use of the fourth version FloTrac system in cardiac output measurement before and after cardiopulmonary bypass. J Clin Monit Comput. 2018. Oct;32(5):807–15. 10.1007/s10877-017-0071-6 [DOI] [PubMed] [Google Scholar]
- Yu J, Che L, Zhu A, Xu L, Huang Y. Goal-Directed Intraoperative Fluid Therapy Benefits Patients Undergoing Major Gynecologic Oncology Surgery: A Controlled Before-and-After Study. Front Oncol. 2022. Apr;12:833273. 10.3389/fonc.2022.833273 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Linton NW, Linton RA. Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb. Br J Anaesth. 2001. Apr;86(4):486–96. 10.1093/bja/86.4.486 [DOI] [PubMed] [Google Scholar]
- Mora B, Ince I, Birkenberg B, Skhirtladze K, Pernicka E, Ankersmit HJ, et al. Validation of cardiac output measurement with the LiDCO™ pulse contour system in patients with impaired left ventricular function after cardiac surgery. Anaesthesia. 2011. Aug;66(8):675–81. 10.1111/j.1365-2044.2011.06754.x [DOI] [PubMed] [Google Scholar]
- Shen Y, Chen X, Hou J, Chen Y, Fang Y, Xue Z, et al. Written on behalf of the AME Thoracic Surgery Collaborative Group. The effect of enhanced recovery after minimally invasive esophagectomy: a randomized controlled trial. Surg Endosc. 2022. Dec;36(12):9113–22. 10.1007/s00464-022-09385-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Xiao W, Duan QF, Fu WY, Chi XZ, Wang FY, Ma DQ, et al. Goal-directed Fluid Therapy May Improve Hemodynamic Stability of Parturient with Hypertensive Disorders of Pregnancy Under Combined Spinal Epidural Anesthesia for Cesarean Delivery and the Well-being of Newborns. Chin Med J (Engl). 2015. Jul;128(14):1922–31. 10.4103/0366-6999.160546 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Asamoto M, Orii R, Otsuji M, Bougaki M, Imai Y, Yamada Y. Reliability of cardiac output measurements using LiDCOrapid™ and FloTrac/Vigileo™ across broad ranges of cardiac output values. J Clin Monit Comput. 2017. Aug;31(4):709–16. 10.1007/s10877-016-9896-7 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Fischer MO, Pellissier A, Saplacan V, Gérard JL, Hanouz JL, Fellahi JL. Cephalic versus digital plethysmographic variability index measurement: a comparative pilot study in cardiac surgery patients. J Cardiothorac Vasc Anesth. 2014. Dec;28(6):1510–5. 10.1053/j.jvca.2014.05.003 [DOI] [PubMed] [Google Scholar]
- Saugel B, Critchley LA, Kaufmann T, Flick M, Kouz K, Vistisen ST, et al. Journal of Clinical Monitoring and Computing end of year summary 2019: hemodynamic monitoring and management. J Clin Monit Comput. 2020. Apr;34(2):207–19. 10.1007/s10877-020-00496-w [DOI] [PMC free article] [PubMed] [Google Scholar]
- Collange O, Jazaerli L, Lejay A, Biermann C, Caillard S, Moulin B, et al. Intraoperative Pleth Variability Index Is Linked to Delayed Graft Function After Kidney Transplantation. Transplant Proc. 2016. Oct;48(8):2615–21. 10.1016/j.transproceed.2016.06.046 [DOI] [PubMed] [Google Scholar]
- Coeckelenbergh S, Delaporte A, Ghoundiwal D, Bidgoli J, Fils JF, Schmartz D, et al. Pleth variability index versus pulse pressure variation for intraoperative goal-directed fluid therapy in patients undergoing low-to-moderate risk abdominal surgery: a randomized controlled trial. BMC Anesthesiol. 2019. Mar;19(1):34. 10.1186/s12871-019-0707-9 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pişkin Ö, Öz II. Accuracy of pleth variability index compared with inferior vena cava diameter to predict fluid responsiveness in mechanically ventilated patients. Medicine (Baltimore). 2017. Nov;96(47):e8889. 10.1097/MD.0000000000008889 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Konur H, Erdogan Kayhan G, Toprak HI, Bucak N, Aydogan MS, Yologlu S, et al. Evaluation of pleth variability index as a predictor of fluid responsiveness during orthotopic liver transplantation. Kaohsiung J Med Sci. 2016. Jul;32(7):373–80. 10.1016/j.kjms.2016.05.014 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Le Guen M, Follin A, Gayat E, Fischler M. The plethysmographic variability index does not predict fluid responsiveness estimated by esophageal Doppler during kidney transplantation: A controlled study. Medicine (Baltimore). 2018. May;97(20):e10723. 10.1097/MD.0000000000010723 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Liu T, Xu C, Wang M, Niu Z, Qi D. Reliability of pleth variability index in predicting preload responsiveness of mechanically ventilated patients under various conditions: a systematic review and meta-analysis. BMC Anesthesiol. 2019. May;19(1):67. 10.1186/s12871-019-0744-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sangkum L, Liu GL, Yu L, Yan H, Kaye AD, Liu H. Minimally invasive or noninvasive cardiac output measurement: an update. J Anesth. 2016. Jun;30(3):461–80. 10.1007/s00540-016-2154-9 [DOI] [PubMed] [Google Scholar]
- Wang Y, Huang W, Han J, Tian Y, Wang C, Li L. A comparison of ClearSight noninvasive cardiac output and pulmonary artery bolus thermodilution cardiac output in cardiac surgery patients. Perioper Med (Lond). 2022. Jun;11(1):24. 10.1186/s13741-022-00248-1 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tanioku T, Yoshida A, Aratani Y, Fujii K, Kawamata T. Validation of noninvasive continuous arterial pressure measurement by ClearSight System™ during induction of anesthesia for cardiovascular surgery. BMC Anesthesiol. 2020. Jul;20(1):176. 10.1186/s12871-020-01091-x [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kanazawa H, Maeda T, Miyazaki E, Hotta N, Ito S, Ohnishi Y. Accuracy and Trending Ability of Blood Pressure and Cardiac Index Measured by ClearSight System in Patients With Reduced Ejection Fraction. J Cardiothorac Vasc Anesth. 2020. Dec;34(12):3293–9. 10.1053/j.jvca.2020.03.045 [DOI] [PubMed] [Google Scholar]
- Stens J, Hering JP, van der Hoeven CW, Boom A, Traast HS, Garmers LE, et al. The added value of cardiac index and pulse pressure variation monitoring to mean arterial pressure-guided volume therapy in moderate-risk abdominal surgery (COGUIDE): a pragmatic multicentre randomised controlled trial. Anaesthesia. 2017. Sep;72(9):1078–87. 10.1111/anae.13834 [DOI] [PubMed] [Google Scholar]
- Fischer MO, Fiant AL, Debroczi S, Boutros M, Pasqualini L, Demonchy M, et al. PANEX3 study group. Perioperative non-invasive haemodynamic optimisation using photoplethysmography: A randomised controlled trial and meta-analysis. Anaesth Crit Care Pain Med. 2020. Jun;39(3):421–8. 10.1016/j.accpm.2020.03.016 [DOI] [PubMed] [Google Scholar]
- Davies SJ, Yates DR, Wilson RJ, Murphy Z, Gibson A, Allgar V, et al. A randomised trial of non-invasive cardiac output monitoring to guide haemodynamic optimisation in high risk patients undergoing urgent surgical repair of proximal femoral fractures (ClearNOF trial NCT02382185). Perioper Med (Lond). 2019. Aug;8(1):8. 10.1186/s13741-019-0119-x [DOI] [PMC free article] [PubMed] [Google Scholar]
- Monnet X, Teboul JL. Transpulmonary thermodilution: advantages and limits. Crit Care. 2017. Jun;21(1):147. 10.1186/s13054-017-1739-5 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bendjelid K, Giraud R, Siegenthaler N, Michard F. Validation of a new transpulmonary thermodilution system to assess global end-diastolic volume and extravascular lung water. Crit Care. 2010;14(6):R209. 10.1186/cc9332 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Goedje O, Hoeke K, Lichtwarck-Aschoff M, Faltchauser A, Lamm P, Reichart B. Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: comparison with pulmonary arterial thermodilution. Crit Care Med. 1999. Nov;27(11):2407–12. 10.1097/00003246-199911000-00014 [DOI] [PubMed] [Google Scholar]
- Jiang Z, Chen J, Gao C, Tan M, Zhang W, Xie Y. Effects of PICCO in the guidance of goal-directed fluid therapy for gastrointestinal function after cytoreductive surgery for ovarian cancer. Am J Transl Res. 2021. May;13(5):4852–9. [PMC free article] [PubMed] [Google Scholar]
- Pavlovic G, Diaper J, Ellenberger C, Frei A, Bendjelid K, Bonhomme F, et al. Impact of early haemodynamic goal-directed therapy in patients undergoing emergency surgery: an open prospective, randomised trial. J Clin Monit Comput. 2016. Feb;30(1):87–99. 10.1007/s10877-015-9691-x [DOI] [PubMed] [Google Scholar]
- Cholley BP, Singer M. Esophageal Doppler: noninvasive cardiac output monitor. Echocardiography. 2003. Nov;20(8):763–9. 10.1111/j.0742-2822.2003.03033.x [DOI] [PubMed] [Google Scholar]
- Singer M. Oesophageal Doppler. Curr Opin Crit Care. 2009. Jun;15(3):244–8. 10.1097/MCC.0b013e32832b7083 [DOI] [PubMed] [Google Scholar]
- Okrainec A, Bergman S, Demyttenaere S, Feldman LS, Nutting A, Carli F, et al. Validation of esophageal Doppler for noninvasive hemodynamic monitoring under pneumoperitoneum. Surg Endosc. 2007. Aug;21(8):1349–53. 10.1007/s00464-006-9106-7 [DOI] [PubMed] [Google Scholar]
- Marik PE. Pulmonary artery catheterization and esophageal doppler monitoring in the ICU. Chest. 1999. Oct;116(4):1085–91. 10.1378/chest.116.4.1085 [DOI] [PubMed] [Google Scholar]
- Kaur U, Sahu S, Srivastava D, Singh TK, Mishra P, Srivastava A. To compare intraoperative goal directed fluid therapy by trans-oesophageal Doppler vis-à-vis FloTrac™ in patients undergoing living related renal transplantation-a prospective randomised controlled study. Indian J Anaesth. 2020. Sep;64(16 Suppl 4):S220–6. 10.4103/ija.IJA_605_20 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Waldron NH, Miller TE, Thacker JK, Manchester AK, White WD, Nardiello J, et al. A prospective comparison of a noninvasive cardiac output monitor versus esophageal Doppler monitor for goal-directed fluid therapy in colorectal surgery patients. Anesth Analg. 2014. May;118(5):966–75. 10.1213/ANE.0000000000000182 [DOI] [PubMed] [Google Scholar]
- Esophageal Doppler Ultrasound-Based Cardiac Output Monitoring for Real-Time Therapeutic Management of Hospitalized Patients. A Review. Agency for Healthcare Research and Quality (US), Rockville (MD); 2007. [PubMed] [Google Scholar]
- Bundgaard-Nielsen M, Holte K, Secher NH, Kehlet H. Monitoring of peri-operative fluid administration by individualized goal-directed therapy. Acta Anaesthesiol Scand. 2007. Mar;51(3):331–40. 10.1111/j.1399-6576.2006.01221.x [DOI] [PubMed] [Google Scholar]
- Tan C, Rubenson D, Srivastava A, Mohan R, Smith MR, Billick K, et al. Left ventricular outflow tract velocity time integral outperforms ejection fraction and Doppler-derived cardiac output for predicting outcomes in a select advanced heart failure cohort. Cardiovasc Ultrasound. 2017. Jul;15(1):18. 10.1186/s12947-017-0109-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gutierrez MC, Moore PG, Liu H. Goal-directed therapy in intraoperative fluid and hemodynamic management. J Biomed Res. 2013. Sep;27(5):357–65. 10.7555/JBR.27.20120128 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Shah SB, Bhargava AK, Hariharan U, Jain CR, Kulkarni A, Gupta N. Goal-directed fluid therapy using transoesophageal echocardiographic inferior venacaval index in patients with low left ventricular ejection fraction undergoing major cytoreductive surgery: A clinical trial. Saudi J Anaesth. 2020;14(1):7–14. 10.4103/sja.SJA_215_19 [DOI] [PMC free article] [PubMed] [Google Scholar]
- de Valk S, Olgers TJ, Holman M, Ismael F, Ligtenberg JJ, Ter Maaten JC. The caval index: an adequate non-invasive ultrasound parameter to predict fluid responsiveness in the emergency department? BMC Anesthesiol. 2014. Dec;14(1):114. 10.1186/1471-2253-14-114 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kumba C. Trans-Thoracic Echocardiographic Aortic Blood Flow Peak Velocity Variation, Distance Minute, Aortic Velocity Time Integral and Postoperative Outcome in Pediatric Surgical Patients—An Observational Pilot Study Protocol. Open Journal of Internal Medicine. 2020;10(1):90–5. 10.4236/ojim.2020.101009 [DOI] [Google Scholar]
- Ganter MT, Geisen M, Hartnack S, Dzemali O, Hofer CK. Prediction of fluid responsiveness in mechanically ventilated cardiac surgical patients: the performance of seven different functional hemodynamic parameters. BMC Anesthesiol. 2018. May;18(1):55. 10.1186/s12871-018-0520-x [DOI] [PMC free article] [PubMed] [Google Scholar]
- Mahjoub Y, Lejeune V, Muller L, Perbet S, Zieleskiewicz L, Bart F, et al. Evaluation of pulse pressure variation validity criteria in critically ill patients: a prospective observational multicentre point-prevalence study. Br J Anaesth. 2014. Apr;112(4):681–5. 10.1093/bja/aet442 [DOI] [PubMed] [Google Scholar]
- Srinivasa S, Kahokehr A, Soop M, Taylor M, Hill AG. Goal-directed fluid therapy- a survey of anaesthetists in the UK, USA, Australia and New Zealand. BMC Anesthesiol. 2013. Feb;13(1):5. 10.1186/1471-2253-13-5 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Edwards MR, Forbes G, MacDonald N, Berdunov V, Mihaylova B, Dias P, et al. OPTIMISE II investigators. Optimisation of Perioperative Cardiovascular Management to Improve Surgical Outcome II (OPTIMISE II) trial: study protocol for a multicentre international trial of cardiac output-guided fluid therapy with low-dose inotrope infusion compared with usual care in patients undergoing major elective gastrointestinal surgery. BMJ Open. 2019. Jan;9(1):e023455. 10.1136/bmjopen-2018-023455 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kenny JS, Clarke G, Myers M, Elfarnawany M, Eibl AM, Eibl JK, et al. A Wireless Wearable Doppler Ultrasound Detects Changing Stroke Volume: Proof-of-Principle Comparison with Trans-Esophageal Echocardiography during Coronary Bypass Surgery. Bioengineering (Basel). 2021. Dec;8(12):203. 10.3390/bioengineering8120203 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kenny JS, Munding CE, Eibl JK, Eibl AM, Long BF, Boyes A, et al. A novel, hands-free ultrasound patch for continuous monitoring of quantitative Doppler in the carotid artery. Sci Rep. 2021. Apr;11(1):7780. 10.1038/s41598-021-87116-y [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wang F, Jin P, Feng Y, Fu J, Wang P, Liu X, et al. Flexible Doppler ultrasound device for the monitoring of blood flow velocity. Sci Adv. 2021. Oct;7(44):eabi9283. 10.1126/sciadv.abi9283 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Scheeren TW, Ramsay MA. New Developments in Hemodynamic Monitoring. J Cardiothorac Vasc Anesth. 2019. Aug;33 Suppl 1:S67–72. 10.1053/j.jvca.2019.03.043 [DOI] [PubMed] [Google Scholar]
- Pleth Variability Index : A Dynamic Measurement to Help Assess Physiology and Fluid Responsiveness. 2013.
- Cannesson M, Besnard C, Durand PG, Bohé J, Jacques D. Relation between respiratory variations in pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure in ventilated patients. Crit Care. 2005. Oct;9(5):R562–8. 10.1186/cc3799 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Brandstrup B, Svendsen PE, Rasmussen M, Belhage B, Rodt SÅ, Hansen B, et al. Which goal for fluid therapy during colorectal surgery is followed by the best outcome: near-maximal stroke volume or zero fluid balance? Br J Anaesth. 2012. Aug;109(2):191–9. 10.1093/bja/aes163 [DOI] [PubMed] [Google Scholar]
- Phan TD, D’Souza B, Rattray MJ, Johnston MJ, Cowie BS, Cowie BS. A randomised controlled trial of fluid restriction compared to oesophageal Doppler-guided goal-directed fluid therapy in elective major colorectal surgery within an Enhanced Recovery After Surgery program. Anaesth Intensive Care. 2014. Nov;42(6):752–60. 10.1177/0310057X1404200611 [DOI] [PubMed] [Google Scholar]
- Aaen AA, Voldby AW, Storm N, Kildsig J, Hansen EG, Zimmermann-Nielsen E, et al. Goal-directed fluid therapy in emergency abdominal surgery: a randomised multicentre trial. Br J Anaesth. 2021. Oct;127(4):521–31. 10.1016/j.bja.2021.06.031 [DOI] [PubMed] [Google Scholar]
- de Waal EE, Frank M, Scheeren TW, Kaufmann T, de Korte-de Boer D, Cox B, et al. Perioperative goal-directed therapy in high-risk abdominal surgery. A multicenter randomized controlled superiority trial. J Clin Anesth. 2021. Dec;75:110506. 10.1016/j.jclinane.2021.110506 [DOI] [PubMed] [Google Scholar]
- Sandham JD, Hull RD, Brant RF, Knox L, Pineo GF, Doig CJ, et al. Canadian Critical Care Clinical Trials Group. A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med. 2003. Jan;348(1):5–14. 10.1056/NEJMoa021108 [DOI] [PubMed] [Google Scholar]
- Pestaña D, Espinosa E, Eden A, Nájera D, Collar L, Aldecoa C, et al. Perioperative goal-directed hemodynamic optimization using noninvasive cardiac output monitoring in major abdominal surgery: a prospective, randomized, multicenter, pragmatic trial: POEMAS Study (PeriOperative goal-directed thErapy in Major Abdominal Surgery). Anesth Analg. 2014. Sep;119(3):579–87. 10.1213/ANE.0000000000000295 [DOI] [PubMed] [Google Scholar]
- Voldby AW, Aaen AA, Møller AM, Brandstrup B. Goal-directed fluid therapy in urgent GAstrointestinal Surgery-study protocol for A Randomised multicentre Trial: the GAS-ART trial. BMJ Open. 2018. Nov;8(11):e022651. 10.1136/bmjopen-2018-022651 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Salzwedel C, Puig J, Carstens A, Bein B, Molnar Z, Kiss K, et al. Perioperative goal-directed hemodynamic therapy based on radial arterial pulse pressure variation and continuous cardiac index trending reduces postoperative complications after major abdominal surgery: a multi-center, prospective, randomized study. Crit Care. 2013. Sep;17(5):R191. 10.1186/cc12885 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Weinberg L, Ianno D, Churilov L, Mcguigan S, Mackley L, Banting J, et al. Goal directed fluid therapy for major liver resection: A multicentre randomized controlled trial. Ann Med Surg (Lond). 2019. Jul;45:45–53. 10.1016/j.amsu.2019.07.003 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Parke RL, Gilder E, Gillham MJ, Walker LJ, Bailey MJ, McGuinness SP, Fluids After Bypass Study Investigators. A Multicenter, Open-Label, Randomized Controlled Trial of a Conservative Fluid Management Strategy Compared With Usual Care in Participants After Cardiac Surgery: The Fluids After Bypass Study. Crit Care Med. 2021. Mar;49(3):449–61. 10.1097/CCM.0000000000004883 [DOI] [PubMed] [Google Scholar]
- Scheeren TW, Wiesenack C, Gerlach H, Marx G. Goal-directed intraoperative fluid therapy guided by stroke volume and its variation in high-risk surgical patients: a prospective randomized multicentre study. J Clin Monit Comput. 2013. Jun;27(3):225–33. 10.1007/s10877-013-9461-6 [DOI] [PubMed] [Google Scholar]
- Diaper J, Schiffer E, Barcelos GK, Luise S, Schorer R, Ellenberger C, et al. Goal-directed hemodynamic therapy versus restrictive normovolemic therapy in major open abdominal surgery: A randomized controlled trial. Surgery. 2021. May;169(5):1164–74. 10.1016/j.surg.2020.09.035 [DOI] [PubMed] [Google Scholar]
- Peng K, Li J, Cheng H, Ji FH. Goal-directed fluid therapy based on stroke volume variations improves fluid management and gastrointestinal perfusion in patients undergoing major orthopedic surgery. Med Princ Pract. 2014;23(5):413–20. 10.1159/000363573 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Weinberg L, Ianno D, Churilov L, Chao I, Scurrah N, Rachbuch C, et al. Restrictive intraoperative fluid optimisation algorithm improves outcomes in patients undergoing pancreaticoduodenectomy: A prospective multicentre randomized controlled trial [Internet]. PLoS One. 2017. Sep;12(9):e0183313. 10.1371/journal.pone.0183313 [DOI] [PMC free article] [PubMed] [Google Scholar]
