Skip to main content
. 2023 Mar 6;13(3):705. doi: 10.3390/life13030705

Table 2.

Dynamics of the length of blood vessels of different diameters (L1 for d < 30 µm, L2 for d = 30–65 µm, and L3 for d > 65 µm) in OCTA images of normal and ischemic intestines after the use of a vacuum stabilizer, Me [Q1;Q3].

Normal Intestine, Experiment Series 1 Ischemic Intestine, Experiment Series 1 Normal Intestine, Experiment Series 2 Ischemic Intestine, Experiment Series 2
Vessel diameter L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3
No vacuum 3.6 [3.1; 4.2] 14.5 [12.5; 16.1] 13.1 [12.1; 14.3] 3.3 [3.2; 4.4] 13.8 [12.7; 17.2] 12.4 [12.2; 13.9] 3.0 [2.9; 3.6] 14.4 [13.2; 14.7] 15.8 [12.9; 15.9] 4.2 [4.1; 4.8] 17.0 [16.3; 17.5] 12.4 [12.2; 13.9]
Vacuum stabilizer 4.3 [3.9; 4.6] 17.8 [16.5; 19.5] 10.7 [9.7; 11.5] 2.6 [2.0; 3.4] 10.5 [8.7; 13.8] 10.7 [10.2; 11.3] 3.7 [3.6; 3.9] 15.4 [15.3; 16.0] 12.9 [11.2; 13.5] 3.5 [2.8; 4.0] 14.6 [12,1; 16.0] 10.4 [9.9; 10.8]
Wilcoxon signed-rank test 0.003 0.001 0.001 0.008 0.004 0.002 0.239 0.025 0.138 0.043 0.128 0.034