Skip to main content
. 2023 Mar 3;12(3):410. doi: 10.3390/pathogens12030410

Table 1.

Type, origin of the sample, and colony forming units (CFU) of detected bacteria during the screening of the ICU environment in General hospital Pula occurring in April 2021.

Origin of the Sample CFU/Sample Detected Bacteria
Powder for gloves in a plastic cup 50 Enterococcus faecalis
Powder for gloves—bulk 0 sterile
Swab from faucet in front of the ICU 105 Pseudomonas aeruginosa
Swab from faucet in isolation box 105 Pseudomonas aeruginosa
Swab from faucet in the middle box 50 Pseudomonas aeruginosa
Swab from patient monitor 1 0 sterile
Swab from patient monitor 2 0 sterile
Swab from faucet in front of the clinic 0 sterile
Swab from water jug in isolation box 0 sterile
Swab from stainless steel table for therapy preparation 0 sterile