Skip to main content
. 2023 Mar 7;15(3):861. doi: 10.3390/pharmaceutics15030861
ARp fitting parameter for cake resistance relationship in Equation (7)
Av cross-section area of the vial
BRp fitting parameter for cake resistance relationship in Equation (7)
∆Hs heat of ice sublimation
Jq heat flux to the product
Jw sublimation flux
kfrozen thermal conductivity of the frozen layer
Kv heat transfer coefficient
L thickness of the product
Ldried thickness of the dried product
Lfroze n thickness of the frozen layer
m mass of ice in the vial
∆m variation of ice by sublimation in the test
pw,i water vapor partial pressure at the interface of sublimation
pw,c water vapor partial pressure in the drying chamber
Rp resistance to mass transfer
Rp, 0 fitting parameter for cake resistance relationship (7)
Sxy sensitivity coefficient of the output quantity y with respect to the input quantity x evaluated at the measurement values
TB product temperature at the bottom of the vial
Ti product temperature at the interface of sublimation
Tshelf shelf (or fluid) temperature
t time
tdrying time required to complete the ice sublimation
U expanded uncertainty
u A (x) standard uncertainty of the quantity x evaluated with type-A method
u B (x) standard uncertainty of the quantity x evaluated with type-B method
u c (x) combined uncertainty of the quantity x
vi interface retreating velocity
ρdried density of the dried product
ρfrozen density of the frozen product