Table 3.
Batch mode adsorption process parameters used in RSM with the equivalent experimental and predicted values for the response.
| Independent variables Cd removal efficiency (%, η) | |||||||
|---|---|---|---|---|---|---|---|
| Std | Run | A | B | C | D | Efficiency | Predicted |
| 19 | 1 | 75 | 0.25 | 5.5 | 50 | 74 | 73.65 |
| 15 | 2 | 50 | 1.75 | 6 | 60 | 94 | 95.39 |
| 6 | 3 | 100 | 0.75 | 6 | 40 | 78.5 | 79.18 |
| 18 | 4 | 125 | 1.25 | 5.5 | 50 | 77 | 76.35 |
| 16 | 5 | 100 | 1.75 | 6 | 60 | 92.3 | 92.47 |
| 3 | 6 | 50 | 1.75 | 5 | 40 | 94.5 | 95.89 |
| 4 | 7 | 100 | 1.75 | 5 | 40 | 90.3 | 90.07 |
| 30 | 8 | 75 | 1.25 | 5.5 | 50 | 98 | 97.25 |
| 27 | 9 | 75 | 1.25 | 5.5 | 50 | 96.5 | 97.25 |
| 14 | 10 | 100 | 0.75 | 6 | 60 | 81.5 | 81.37 |
| 17 | 11 | 25 | 1.25 | 5.5 | 50 | 87.9 | 88.06 |
| 29 | 12 | 75 | 1.25 | 5.5 | 50 | 97.5 | 97.25 |
| 26 | 13 | 75 | 1.25 | 5.5 | 50 | 97.5 | 97.25 |
| 25 | 14 | 75 | 1.25 | 5.5 | 50 | 96.5 | 97.25 |
| 2 | 15 | 100 | 0.75 | 5 | 40 | 74.6 | 74.47 |
| 1 | 16 | 50 | 0.75 | 5 | 40 | 84.2 | 83.27 |
| 13 | 17 | 50 | 0.75 | 6 | 60 | 87.8 | 87.27 |
| 7 | 18 | 50 | 1.75 | 6 | 40 | 97.3 | 95.95 |
| 28 | 19 | 75 | 1.25 | 5.5 | 50 | 97.5 | 97.25 |
| 23 | 20 | 75 | 1.25 | 5.5 | 30 | 91.9 | 91.88 |
| 9 | 21 | 50 | 0.75 | 5 | 60 | 84.8 | 85.70 |
| 21 | 22 | 75 | 1.25 | 4.5 | 50 | 88 | 87.93 |
| 20 | 23 | 75 | 2.25 | 5.5 | 50 | 97.5 | 97.36 |
| 8 | 24 | 100 | 1.75 | 6 | 40 | 92.3 | 92.65 |
| 5 | 25 | 50 | 0.75 | 6 | 40 | 84.7 | 85.45 |
| 24 | 26 | 75 | 1.25 | 5.5 | 70 | 94.6 | 94.13 |
| 11 | 27 | 50 | 1.75 | 5 | 60 | 97.4 | 95.95 |
| 22 | 28 | 75 | 1.25 | 6.5 | 50 | 92.5 | 92.08 |
| 12 | 29 | 100 | 1.75 | 5 | 60 | 90 | 90.50 |
| 10 | 30 | 100 | 0.75 | 5 | 60 | 76.7 | 77.28 |