Performance of clinical and radiomic models.

Model AUC Sensitivity Specificity Accuracy P value
Training cohort
 Clinical model 0.723 0.795 0.594 0.669
 Radiomics model T2WI 0.839 0.833 0.800 0.814
ADC 0.938 0.897 0.848 0.864
ADC+T2WI 0.942 0.841 0.905 0.881 <0.001 d
 Combined model 0.955 0.886 0.905 0.898 0.214 e
Validation cohort
 Clinical model 0.745 0.632 0.844 0.765
 Radiomics model T2WI 0.809 0.867 0.722 0.765
ADC 0.869 0.833 0.815 0.824
ADC+T2WI 0.910 0.947 0.844 0.882 0.026 d
 Combined model 0.931 0.895 0.875 0.882 0.277 e