TABLE 3.

Pacemaker characteristics.

Total (n = 89) Univentricular (n = 19) Biventricular (n = 70) p value
Pacemaker lead position
Epicardial 85 (96%) 19 (100%) 66 (94%) .574
Transvenous 4 (4%) 0 (0%) 4 (6%)
Pacemaker system
Atrial 6 (7%) 4 (21%) 2 (3%) .0014
Ventricular 18 (20%) 0 (0%) 18 (26%)
Dual chamber 65 (73%) 15 (79%) 50 (71%)
Ventricular pacing
<50% 27 (30%) 9 (47%) 18 (26%) .092
>50% 62 (70%) 10 (53%) 52 (74%)
Ventricular lead position
Apex 44 (54%) 8 (53%) 36 (54%) >.99
Nonapical 38 (46%) 7 (47%) 31 (46%)
Ventricle paced
Subpulmonary 32 (39%) 0 (0%) 32 (47%) .0003
Systemic 51 (61%) 15 (100%) 36 (53%)
Paced QRS width (ms)
<140 15 (24%) 1 (10%) 14 (27%) .427
≥140 47 (76%) 9 (90%) 38 (73%)
Complications postimplantation
No 79 (89%) 17 (89%) 62 (89%) >.99
Yes 10 (11%) 2 (11%) 8 (11%)
Reoperation within a month
No 82 (92%) 18 (95%) 64 (91%) >.99
Yes 7 (8%) 1 (5%) 6 (9%)
Long‐term pacing complications
No 82 (92%) 19 (100%) 63 (90%)
Yes 7 (8%) 0 (0%) 7 (10%)
Pacemaker replacement
No 28 (31%) 8 (42%) 20 (29%)
Yes 61 (69%) 11 (58%) 50 (71%)
Number of replacements
Median [IQR] 1 [0–2] 1 [0–1.5] 1 [0–2]

Note: Comparison of the pacemaker characteristics between the two groups.

Bold indicates p value <.05, demonstrating statistical significance.