Skip to main content
. 2023 Apr 8;41(4):366–375. [Article in Chinese] doi: 10.3724/SP.J.1123.2022.05016

表4.

尿液中7种苯系物代谢物在3个加标水平下的回收率和日内、日间精密度(n=6)

Compound Spiked/
(μg/L)
Recovery/
%
Intra-day
precision/%
Inter-day
precision/%
MU 10.0 113 3.5 7.1
100 106 2.0 5.7
1000 104 3.9 4.5
PMA 0.2 105 4.9 7.9
2.0 101 6.3 3.3
20 108 8.6 1.9
BMA 2.0 104 2.8 7.6
20.0 103 1.8 3.0
200 105 3.2 3.5
HA 1000 86 5.0 21.4
10000 84 3.6 14.5
100000 85 2.8 6.1
2MHA 2.0 111 2.9 4.1
20.0 103 3.3 3.1
200 106 4.7 3.2
3MHA+4MHA 2.0 109 8.2 4.1
20.0 123 4.2 5.4
200 119 7.3 4.7