Skip to main content
. 2023 Mar;64(3):444–451. doi: 10.2967/jnumed.122.264371

TABLE 5.

Initial and Revised Algorithms for Interpreting MK-6240 PET

Scan assessment Original algorithm Refined algorithm Reason for adjustment
Negative No more than one region positive in cortex All clusters negative Allowing one region to be positive was to prevent interpretation of scans as positive when meningeal uptake near inferolateral temporal lobes could be misread as positive region; this was dropped with improved methods or instructions to identify this confounder
Positive, AD pattern Evidence of increased uptake in two cortical regions with at least one region in temporal lobes At least one cluster 1 region positive and no cluster 3 regions positive Revision was made after observation of multiple cases with isolated cluster 1 abnormality in just one region
Positive, atypical AD pattern Not assessed Increased uptake in one or more regions in cluster 2 but not in clusters 1 or 3 This rare pattern was noted from review of other MK-6240 datasets and was expected pattern based on published literature on other tau PET tracers