Skip to main content
. Author manuscript; available in PMC: 2023 Apr 5.
Published in final edited form as: J Occup Environ Hyg. 2021 May 26;18(7):305–313. doi: 10.1080/15459624.2021.1919685

Table 3.

Protection class (PC) and protection level (PL) for elastomeric half-facepiece (EHR), full-facepiece, and powered air-purifying (PAPR) respirators using the Second Highest TIL Method ISO.

Respirator Model Aerosol GM Fit Factor GM TIL (%) GSD Second Highest TIL (%) PC PL
EHR A NaCl 1507 0.056 5.57 0.614 3 30
Corn oil 0.197* 4.03 1.048 2 10
B NaCl 1667 0.038 6.48 0.799 3 30
Corn oil 0.086* 9.19 1.852 2 10
Full-facepiece C NaCl 4670 0.049 2.22 0.128 3 30
Corn oil 0.046 1.84 0.089 4 250
D NaCl 7753 0.016 1.84 0.054 4 250
Corn oil 0.015 3.20 0.064 4 250
PAPR E NaCl 7731 0.010** 1.57 0.021 4 250
Tight-fitting Corn oil 0.003 3.31 0.003 5 2000
F NaCl 3799 0.011 ** 1.52 0.019 4 250
Corn oil 0.002 1.53 0.019 4 250
PAPR G NaCl N/A 0.013** 1.83 0.026 4 250
Loose-fitting Corn oil 0.003 2.83 0.022 4 250
H NaCl N/A 0.015** 2.27 0.026 4 250
Corn oil 0.002 1.47 0.003 5 2000

ISO ISO/CD (2018) recommended method.

*

Significantly larger for corn oil aerosol than for NaCl aerosol.

**

Significantly larger for NaCl aerosol than for corn oil aerosol.