Skip to main content
. 2023 Mar 24;17:1113867. doi: 10.3389/fnins.2023.1113867

Table 2.

Experimental results for stimulation of the extensor muscle and the nerve.

0 ms 5 ms 10 ms 15 ms 20 ms
Flexor voltage, V 10 ± 3.5 9.2 ± 3.7 9.2 ± 3.7 9.4 ± 4.4 9.4 ± 3.8
Extensor voltage, V 25.4 ± 4.6 25.4 ± 4.6 25.4 ± 4.6 25.4 ± 4.6 25.4 ± 4.6
Extensor force, kgf, mean±std 1.60 ± 0.84 1.30 ± 0.38 1.19 ± 0.23 0.93 ± 0.31 1.00 ± 0.40
Extensor force with inhibition, kgf, mean±std 0.44 ± 0.34 0.37 ± 0.30 0.31 ± 0.17 0.16 ± 0.06 0.18 ± 0.07