Table 1. The imaging parameters for MRE-MRI, T1WI, and T2WI sequences.

Parameter MRE imaging Coronal T2WI Axial T2WI Axial T1WI
Repetition time (ms) 1,600 1,000 1,650 150
Echo time (ms) 54.2 68 26 1.4/2
Flip angle (degrees) 180 150 111 75
Section thickness (mm) 3.6 3 5 5
Matrix# 96×96 320×256 320×256 256×205
Field of view* (mm) 400×400 452×452 378×276 438×285
Acquisition time (s) 1 min 8 s 27 s 1 min 7 s 33 s
MEG (Hz) 80
Direction of scan Coronal/axial Coronal Axial Axial
Breath-holding Yes Yes Yes Yes

Matrix# indicates the number of pixel in frequency coding direction × the number of pixel in phase coding direction. Field of view* indicates the image actual size in frequency coding direction × the image actual size in phase coding direction. MRE, magnetic resonance elastography; MRI, magnetic resonance imaging; T1WI, T1 weighted imaging; T2WI, T2 weighted imaging; MEG, motion encoding gradient.