Table 1.

Measurements of the lamp using the optical power meter along with the corresponding calculated 8‐h doses.

Sensor configuration Height (m) Offset
0 m 0.5 m 1.0 m
Measured Irradiance (μW cm−2)
Horizontal irradiance 1.8 3.100 3.100 0.300
1.3 1.200 1.700 1.100
Direct irradiance (meter directed at fixture) 1.8 3.100 3.700 0.550
1.3 1.200 1.800 1.400
Vertical irradiance 1.8 0.025 1.300 0.300
1.3 0.018 0.260 0.530
Calculated 8‐h dose (mJ cm−2)
Horizontal irradiance 1.8 89.280 89.280 8.640
1.3 34.560 48.960 31.680
Direct irradiance (meter directed at fixture) 1.8 89.280 106.560 15.840
1.3 34.560 51.840 40.320
Vertical irradiance 1.8 0.720 37.440 8.640
1.3 0.518 7.488 15.264

The maximum calculated 8‐h dose was chosen as the maximum directly measured dose (106.56 mJ cm−2 for this study, bolded text).