Table 1.
Measurements of the lamp using the optical power meter along with the corresponding calculated 8‐h doses.
| Sensor configuration | Height (m) | Offset | ||
|---|---|---|---|---|
| 0 m | 0.5 m | 1.0 m | ||
| Measured Irradiance (μW cm−2) | ||||
| Horizontal irradiance | 1.8 | 3.100 | 3.100 | 0.300 |
| 1.3 | 1.200 | 1.700 | 1.100 | |
| Direct irradiance (meter directed at fixture) | 1.8 | 3.100 | 3.700 | 0.550 |
| 1.3 | 1.200 | 1.800 | 1.400 | |
| Vertical irradiance | 1.8 | 0.025 | 1.300 | 0.300 |
| 1.3 | 0.018 | 0.260 | 0.530 | |
| Calculated 8‐h dose (mJ cm−2) | ||||
| Horizontal irradiance | 1.8 | 89.280 | 89.280 | 8.640 |
| 1.3 | 34.560 | 48.960 | 31.680 | |
| Direct irradiance (meter directed at fixture) | 1.8 | 89.280 | 106.560 | 15.840 |
| 1.3 | 34.560 | 51.840 | 40.320 | |
| Vertical irradiance | 1.8 | 0.720 | 37.440 | 8.640 |
| 1.3 | 0.518 | 7.488 | 15.264 | |
The maximum calculated 8‐h dose was chosen as the maximum directly measured dose (106.56 mJ cm−2 for this study, bolded text).