Skip to main content
. Author manuscript; available in PMC: 2023 Apr 12.
Published in final edited form as: Ind Eng Chem Res. 2022;61(31):10.1021/acs.iecr.2c01924. doi: 10.1021/acs.iecr.2c01924

Table 1.

Refrigerant Samples Used in This Study Listed with Molar Masses, Source, CAS Numbers, and Puritya

Chemical Name Molar Mass/g·mol−1 Source CAS Numbers Purity/mole fraction
2,3,3,3-tetrafluoropropene (R-1234yf) 114.04 Chemours 754–12-1 0.999
1,1,1,2-tetrafluoroethane (R-134a) 102.03 Dupont 811–97-2 0.999
trans-1,3,3,3-tetrafluoropropene (R-1234ze(E)) 114.04 Honeywell 29118–24-9 0.9997
a

All samples were degassed using a freeze–pump–thaw method before preparing mixtures. Sample purities were verified through gas chromatography.