Table 1.
DTI | T2-Relaxometry | T2w | |
---|---|---|---|
Repetition time (TR) | 3990 ms | 2400 ms | 8150 ms |
Echo time (TE) | 72 ms | 12 echoes (10, 20, …, 120 ms) | 54 ms |
Field of view (FOV) | 178 × 178 mm2 | 160 × 160 mm2 | 160 × 160 mm2 |
Matrix | 102 × 128 | 338 × 334 | 512 × 333 |
Slice thickness | 3.0 mm | 3.5 mm | 3.5 mm |
Number of slices | 18 | 11 | 41 |
Slice gap | 0.3 mm | None | 0.35 mm |
Number of averages | 1 | 1 | 2 |
Parallel imaging | GRAPPA | None | GRAPPA |
Acceleration factor | 2 | n.a. | 2 |
Refocusing flip angle | 180° | 180° | 150° |
Bandwidth | 930 Hz/px | 190 Hz/px | 181 Hz/px |
Acquisition time per slab | 8:36 min | 6:43 min | 3:56 min |
Fat saturation | Spectral fat saturation | Spectral fat saturation | Spectral fat saturation |
Number of diffusion directions | 20 | n.a. | n.a. |
b-values | 0 and 1000 s/mm2 | n.a. | n.a. |
Abbreviations: DTI, diffusion tensor imaging; T2w, T2-weighted sequence; GRAPPA, generalized autocalibrating partial parallel acquisition.