Table 1.
The two significant, non-redundant radiomic features selected as input into the ML model for each image type. Feature definitions: https://pyradiomics.readthedocs.io/en/latest/features.html
| Image type | Features for classification |
|---|---|
| 50 keV VMI | GLDM_DependenceVariance GLRLM_GrayLevelNonUniformity |
| 70 keV VMI | GLCM_Imc1 (Informational Measure of Correlation 1) GLDM_DependenceNonUniformityNormalized |
| 100 keV VMI | firstorder_RootMeanSquared GLSZM_ZonePercentage |
| Iodine map | firstorder_Minimum GLRLM_RunVariance |
| VNC | GLSZM_ZonePercentage NGTDM_Complexity |