Table 11.
Exergoeconomic parameters of the ORC configurations.
Components |
|
|
|
|
|
|
|
---|---|---|---|---|---|---|---|
Basic ORC | |||||||
Pump | 16.63 | 45.18 | 0.09 | 0.006 | 171.7 | 85.83 | 0.0347 |
Evaporator | 4.00 | 5.58 | 6.16 | 0.089 | 39.41 | 28.92 | 0.0361 |
Expander | 6.27 | 16.63 | 3.42 | 0.077 | 165.1 | 86.69 | 0.5034 |
Condenser | 6.27 | 40.78 | 2.23 | 0.051 | 550.0 | 63.31 | 0.0887 |
IHE-ORC | |||||||
IHE | 6.67 | 35.09 | 0.40 | 0.009 | 425.7 | 85.20 | 0.0551 |
Pump | 16.84 | 44.71 | 0.11 | 0.006 | 165.5 | 85.30 | 0.0374 |
Evaporator | 4.00 | 5.22 | 4.47 | 0.064 | 30.51 | 38.42 | 0.0402 |
Expander | 6.67 | 16.84 | 3.80 | 0.091 | 152.3 | 85.58 | 0.5415 |
Condenser | 6.67 | 58.12 | 1.72 | 0.041 | 770.8 | 78.13 | 0.1481 |
FFH-ORC | |||||||
FFH | 7.28 | 10.94 | 1.76 | 0.046 | 50.32 | 6.52 | 0.0032 |
Pump-I | 16.30 | 55.62 | 0.03 | 0.002 | 241.3 | 89.90 | 0.0142 |
Pump-II | 16.30 | 42.64 | 0.09 | 0.005 | 161.6 | 87.82 | 0.0365 |
Evaporator | 4.00 | 4.99 | 2.39 | 0.034 | 24.85 | 62.83 | 0.0583 |
Expander | 6.28 | 16.30 | 3.81 | 0.086 | 159.5 | 86.42 | 0.5479 |
Condenser | 6.28 | 32.11 | 1.95 | 0.044 | 411.3 | 65.5 | 0.0839 |
IHE-FFH-ORC | |||||||
IHE | 5.55 | 9.60 | 0.40 | 0.008 | 73.0 | 10.49 | 0.0009 |
FFH | 7.97 | 9.48 | 0.39 | 0.003 | 18.96 | 21.57 | 0.0031 |
Pump-I | 16.93 | 58.25 | 0.02 | 0.001 | 244.0 | 90.09 | 0.0124 |
Pump-II | 17.46 | 44.01 | 0.09 | 0.006 | 152.1 | 86.81 | 0.0371 |
Evaporator | 4.00 | 4.47 | 2.96 | 0.042 | 11.7 | 0.05 | 0.0021 |
HPE | 5.55 | 16.93 | 1.98 | 0.039 | 205.1 | 90.27 | 0.3673 |
LPE | 5.55 | 17.46 | 1.89 | 0.038 | 214.5 | 89.83 | 0.3347 |
Condenser | 5.55 | 42.3 | 2.33 | 0.046 | 662.1 | 6.94 | 0.0035 |