ηth, ηex, C˙sis, and Cel results and S/N ratios according to L18 orthogonal array.

Exp.No Control factors and levels
Responses
S/N ratios
A B C D E F G ηth ηex C˙sys ($/h) Cel
($/kWh)
ηth ηex C˙sys Cel
1 1 1 1 1 1 1 1 0.13 0.58 0.767 0.045 −17.5 −4.8 2.3 27.0
2 1 2 2 2 2 2 2 0.17 0.60 0.878 0.042 −15.3 −4.4 1.1 27.6
3 1 3 3 3 3 3 3 0.19 0.61 0.932 0.040 −14.3 −4.3 0.6 27.9
4 2 1 1 2 2 3 3 0.15 0.64 0.844 0.043 −16.4 −3.9 1.5 27.4
5 2 2 2 3 3 1 1 0.19 0.67 0.897 0.040 −14.4 −3.5 0.9 27.9
6 2 3 3 1 1 2 2 0.15 0.49 0.929 0.046 −16.4 −6.3 0.6 26.8
7 3 1 2 1 3 2 3 0.11 0.50 0.739 0.047 −18.8 −6.0 2.6 26.5
8 3 2 3 2 1 3 1 0.15 0.53 0.858 0.045 −16.2 −5.5 1.3 26.9
9 3 3 1 3 2 1 2 0.23 0.73 1.049 0.040 −12.9 −2.7 −0.4 28.1
10 4 1 3 3 2 2 1 0.12 0.53 0.684 0.048 −18.3 −5.5 3.3 26.3
11 4 2 1 1 3 3 2 0.16 0.55 1.005 0.045 −15.8 −5.2 0.0 26.9
12 4 3 2 2 1 1 3 0.17 0.56 1.099 0.048 −15.4 −5.1 −0.8 26.4
13 5 1 2 3 1 3 2 0.14 0.59 0.845 0.048 −17.1 −4.6 1.5 26.5
14 5 2 3 1 2 1 3 0.12 0.43 1.017 0.055 −18.2 −7.2 −0.1 25.4
15 5 3 1 2 3 2 1 0.19 0.61 1.192 0.046 −14.4 −4.3 −1.5 27.0
16 6 1 3 2 3 1 2 0.11 0.47 0.691 0.052 −19.3 −6.6 3.2 25.6
17 6 2 1 3 1 2 3 0.20 0.70 1.102 0.044 −14.1 −3.1 −0.8 27.0
18 6 3 2 1 2 3 1 0.16 0.49 1.090 0.050 −16.1 −6.1 −0.7 25.7