Skip to main content
. 2023 Mar 1;13(4):2262–2277. doi: 10.21037/qims-22-596

Table 2. Quantitative measures of LV function and strain.

Parameters SegBH, mean ± SD RTCSCineMoCo RTCSCine
Mean ± SD P value* r Mean ± SD P value* r
LVEF (%) 57.4±13.7 57.3±13.1 0.837 0.985 55.6±13.1 <0.001 0.963
LVEDV (mL) 125.0±46.7 126.1±45.9 0.164 0.992 126.2±47.1 0.283 0.984
LVESV (mL) 56.2±37.1 56.5±36.4 0.587 0.995 59.0±38.0 <0.001 0.991
LVSV (mL) 68.8±23.5 69.6±22.9 0.163 0.983 67.2±22.6 0.058 0.953
LVM (g) 91.2±32.0 90.7±33.2 0.457 0.987 85.8±33.9 <0.001 0.946
GRS (%) 29.0±11.4 27.9±10.4 0.022 0.944 26.3±10.1 <0.001 0.917
GCS (%) −17.0±4.8 −16.2±4.3 <0.001 0.952 −15.4±4.3 <0.001 0.922
GLS (%) −15.8±4.0 −11.7±3.9 <0.001 0.803 −10.2±2.9 <0.001 0.712
TPSR (ms) 303.8±42.2 300.4±45.7 0.348 0.785 299.1±43.6 0.175 0.789
TPSC (ms) 303.4±42.8 299.9±45.9 0.308 0.808 299.5±44.6 0.308 0.750
TPSL (ms) 317.4±53.8 306.6±55.6 0.114 0.766 305.0±55.8 0.011 0.753

Measurements of RTCSCineMoCo and RTCSCine were analyzed using SegBH as a reference standard. *, P values were obtained by paired t-test; , P<0.05, RTCSCineMoCo versus SegBH; , P<0.05, RTCSCine versus SegBH. GCS, global circumferential strain; GLS, global longitudinal strain; GRS, global radial strain; LV, left ventricular; LVEDV, left ventricular end-diastolic volume; LVEF, left ventricular ejection fraction; LVESV, left ventricular end-systolic volume; LVM, left ventricular mass; LVSV, left ventricular stroke volume; r, correlation coefficient; RTCSCine, real-time cine imaging with compressed sensing; RTCSCineMoCo, real-time cine imaging combines compressed sensing reconstruction and retrospective fully automated respiratory motion correction; SD, standard deviation; SegBH, segmented acquisition with retrospective electrocardiogram gating and breath-hold; TPSC, time to peak strain in circumferential; TPSL, time to peak strain in longitudinal; TPSR, time to peak strain in radial.