Skip to main content
. 2023 Apr 3;14:1132087. doi: 10.3389/fphar.2023.1132087

TABLE 4.

Effects of PSPL extract on hematological parameters in the acute toxicity study. Values are expressed as means ± SEM. The letters indicate significant differences (p < 0.05). Hb, hemoglobin; RBC, red blood cell; RDW, red cell distribution width; PCV, packed cell volume; MCV, mean corpuscular volume; MCH, mean corpuscular hemoglobin; MCHC, mean corpuscular hemoglobin concentration; WBC, white blood cell; AC, acute control group; AT 2000, 2,000 mg/kg of PSPL.

Parameters AC AT 2000
Hb (g/dL) 16.4 ± 0.36 16.59 ± 0.81
RBC (x10^12/L) 9.14 ± 0.33 9.28 ± 0.53
RDW (%) 17.17 ± 0.79 17.13 ± 1.10
PCV (%) 59.67 ± 2.33 57.67 ± 3.18
MCV (fL) 65.00 ± 0.58a 62.00 ± 0b
MCH (pg) 17.67 ± 0.33 18.00 ± 0
MCHC (g/dL) 27.67 ± 0.33a 29.33 ± 0.33b
WBC (x10^9/L) 13.67 ± 1.03 16.70 ± 1.76
Neutrophils (x10^9/L) 2.07 ± 0.37 2.27 ± 0.41
Lymphocytes (x10^9/L) 9.97 ± 0.73 13.10 ± 1.69
Monocytes (x10^9/L) 1.40 ± 0.12 1.03 ± 0.37
Eosinophils (x10^9/L) 0.19 ± 0.04 0.19 ± 0.18
Basophils (x10^9/L) 0.07 ± 0.03 0.10 ± 0.00
Platelet (x10^9/L) 1,235.00 ± 124.82 1,390.67 ± 183.97