Skip to main content
. 2023 Jan 12;62(7):e202212063. doi: 10.1002/anie.202212063

Table 1.

Lag time (t lag), elongation rate (k), remaining monomer concentration determined by SEC and maximum fluorescence after performing ThT‐based kinetic assays.

Solvent

Salt concentration

t lag [hours]

k [h−1]

Remaining Monomer [μM]

% max fluorescence at 160 hours

H2O

NaCl 150 mM

34.3±4.9

0.84±0.01

12.8±9.0

30.3±14.9

NaCl 1.5 M

31.0±5.1

7.7±5.9

0

72.6±11.5

CsI 150 mM

nd[a]

0.06±0.05

38.1±7.8

7.9±6.5

CsI 1.5 M

nd[a]

0.01±0.01

35.9±16.6

2.1±1.0

D2O

NaCl 150 mM

23.8±4.0

2.5±0.6

2.0±3.0

98.1±0.9

NaCl 1.5 M

19.0±2.6

6.1±2.5

0

69.0±15.3

CsI 150 mM

39.3±0.9

0.65±0.36

11.7±2.7

59.1±25.1

CsI 1.5 M

nd[a]

0.32±0.23

0

12.8±8.2

[a] nd not determined due to lack of detectable ThT fluorescence signal.