The mean electrophysiological parameters of CIDP patients with upregulation of microRNA-31 expression.

Nerve conduction Electrophysiological parameters Patients
n = 5
Motor Median (wrist-elbow) Latency (ms) 6.38
Amplitude (mV) 7.08
CV (m/s) 47.4
Ulnar (wrist-elbow) Latency (ms) 2.96
Amplitude (mV) 8.78
CV (m/s) 47.2
Peroneal (ankle head of fibula) Latency (ms) 6.28
Amplitude (mV) 2.12
CV (m/s) 40.8
Tibial (ankle popliteal fossa) Latency (ms) 6.68
Amplitude (mV) 3.30
CV (m/s) 38.10
Sensory Median (digit II) Latency (ms) 3.52
Amplitude (μV) 11.30
CV (m/s) 48.80
Ulnar (digit V) Latency (ms) 2.72
Amplitude (μV) 11.90
CV (m/s) 44.60
Sural Latency (ms) 3.61
Amplitude (μV) 4.20
CV (m/s) 44.10
F-wave studies Median F-latency (ms) 32.76
Ulnar 32.48
Peroneal 68.89
Tibial 65.76