. 2023 Apr 18;13(17):11853–11864. doi: 10.1039/d3ra01168b

Fig. 7. TCE degradation curve (red) and corresponding Cl release curve (green), the theoretical 2-fold and 3-fold Cl release curves (blue and cyan, respectively) were calculated based on the Cl content of degraded TCE, which was determined by the difference between the degradation curve (red) and the blank control of TCE in water (black). (SD, n = 2).