Table 1. The table presents a comparison of two sets of measurements, "pre-intervention" and "post-intervention", pertaining to regions of interest (ROIs) 1 and 2, alongside relevant evaluation metrics for radiotherapy contouring of the right cochlea.
[10]
| Measurement | Pre-intervention | Post-intervention |
| ROI 1 Volume (cc) | 0.12 | 0.12 |
| ROI 2 Volume (cc) | 0.09 | 0.08 |
| Matching Volume (cc) | 0.06 | 0.08 |
| Extra Volume (cc) | 0.03 | 0.00 |
| Missing Volume (cc) | 0.06 | 0.04 |
| Forgiven Volume (Extra) (cc) | 0.02 | 0.00 |
| Forgiven Volume (Missing) (cc) | 0.03 | 0.04 |
| Dice Coefficient | 0.62 | 0.80 |
| StructSure™ Score | 88.81 | 99.15 |
| Forgiveness Region (mm) | 1.00 | 1.00 |
| Penalty Slope (voxel penalty/mm) | 0.50 | 0.50 |
| Max Distance Threshold (mm) | 10.00 | 10.00 |