Table 3. The table presents a comparison of two sets of measurements, "pre-intervention" and "post-intervention", pertaining to regions of interest (ROIs) 1 and 2, alongside relevant evaluation metrics for radiotherapy contouring of the left cochlea.
[10]
| Measurement | Pre-Intervention | Post-Intervention |
| ROI 1 Volume (cc) | 0.14 | 0.14 |
| ROI 2 Volume (cc) | 0.12 | 0.15 |
| Matching Volume (cc) | 0.10 | 0.12 |
| Extra Volume (cc) | 0.03 | 0.02 |
| Missing Volume (cc) | 0.04 | 0.02 |
| Forgiven Volume [Extra] (cc) | 0.03 | 0.02 |
| Forgiven Volume [Missing] (cc) | 0.01 | 0.02 |
| Dice Coefficient | 0.73 | 0.86 |
| StructSure™ Score | 88.45 | 99.85 |
| Forgiveness Region (mm) | 1.00 | 1.00 |
| Penalty Slope (voxel penalty/mm) | 0.50 | 0.50 |
| Max Distance Threshold (mm) | 10.00 | 10.00 |