Table 2.

MRI sequence acquisition parameters. Median value displayed with range of values shown in parenthesis. No parenthesis indicates all values were the same for all patients.

Acquisition Parameter T2W DWI

Repetition time (ms) 4800 5000 (1500–7000)
Echo time (ms) 80 65 (50–102)
Echo train length 15 15 (0–63)
Flip angle (°) 180 (166–180) 120 (90–180)
Slice thickness (mm) 2 4
In-plane resolution (mm) 0.5 2.0 (1.0–2.0)
Slice gap (mm) 2 4
Acquisition matrix 256×230 128×128
Pixel bandwidth (Hz/px) 300 870 (750–1220)
Number of averages 1 2
Number of axial slices 120 28 (24–48)

T2W, T2-weighted magnetic resonance imaging; DWI, diffusion-weighted magnetic resonance imaging.