Skip to main content
. 2023 Apr 10;120(5):e20220756. [Article in Portuguese] doi: 10.36660/abc.20220756

Table 4. – Comparison of blood pressure and heart rate variability before and after IF in patients with HT.

  Before IF Mean±SD After IF Mean±SD Comparison
Systolic blood pressure (24 Hours) 139.48±12.26 126.44±7.93 p<0.001
Diastolic blood pressure (24 Hours) 84.26±7.54 76.35±5.36 p=0.014
Night Systolic blood pressure 133.35±15.46 123.45±10.56 p<0.001
Night Diastolic blood pressure 79.45±10.64 71.35±6.45 p<0.001
Maximum Heart Rate (beats/min) 156.21±13.55 148.42±14.60 p=0.041
Minimum Heart Rate (beats/min) 65.43±10.42 64.86±10.25 p=0.634
Average Heart rate (24 Hours) 86.93 ± 10.44 74.55 ± 12.78 p=0.042
Average Heart Rate Night 69.48±10.51 72.70±10.26 p=0.067
HF power 193.93±63.02 216.00±76.07 p=0.039
LF/HF value 4.75±1.36 3.95±1.49 p=0.041
SDNN (ms) 126.16 ± 32.85 137.48 ± 30.56 p=0.059
RMSSD (ms) 33.76 ± 14.39 37.02 ± 11.35 p=0.042
pNN50 (%) 6.68 ±2.51 8.20±2.91 p=0.063

High-frequency (HF) power, the ratio of low-high frequency (LF/HF), SDNN (standard deviation of all normal to normal RR [NN] intervals), RMSSD (the mean root square of the sum of squares of differences between adjacent NN intervals), pNN50 (the number of pairs of NN intervals that differ by more than 50 ms). Paired t-test