Skip to main content
. 2023 Apr 11;10:1057685. doi: 10.3389/fmed.2023.1057685

TABLE 1.

Details of the reviewed studies.

References Intervention Outcomes Setting Patients (eyes) Keratome/laser type(s) (flap creation) Laser type(s) (stromal ablation) Flap/hinge technical characteristic Tests used Follow-up intervals
Lee et al. (95) Hinge position RR and DES South Korea, same center 30 (50) • Hansatome (Bausch & Lomb Surgical) or the M2 (Moria): superior hinge (25)
• SCMD (New United Development Corp.) or the Summit Krumeich-Barraquer (SKBM, Alcon Surgical): nasal hinge (25)
Star S2 excimer laser (VISX)
• Flap thickness:
• 160 μm
• Flap diameter:
• 8.5 mm
• BUT
• ST (without anesthesia)
2 months
Donenfeld et al. (96) Hinge position CS and DES USA, same center, same surgeon 52 (104) • Hansatome microkeratome (Bausch & Lomb, Rochester, NY, USA): superior hinge
• Amadeus microkeratome (Allergan Pharmaceuticals, Irvine, CA, USA): nasal hinge
VISX Star II excimer laser (VISX, Inc., Santa Clara, CA, USA) • Flap thickness:
• 160 μm
• Flap diameter:
• 9.5 mm
• Masked Cochet–Bonnet esthesiometry
• LGS (corneal and conjunctival)
• ST (with anesthesia)
• TBUT
• Subjective evaluation of DE sensation
1 week
1 month
3 months
6 months
Donenfeld et al. (74) Hinge width CS and DES USA, same center, same surgeon 54 (108) • Amadeus microkeratome: nasal hinge (horizontal flap) VISX Star 3 excimer laser • Flap thickness:
• 160 μm
• Flap diameter:
• 9.5 mm
• Hinge widths:
• 0.6 mm vs. 1.2 mm
• Cochet-Bonnet esthesiometry
• LGS (corneal and conjunctival)
• ST (with anesthesia)
• TBUT
1 week
1 month
3 months
6 months
Nassaralla et al.(97) Hinge position and flap thickness CS Brazil, Same center, Same surgeon, 1 (right) eye of each patient 40 (40) • Hansatome microkeratome: superior hinge
• ACS microkeratome: nasal hinge
Technolas 217-C Excimer laser (Bausch & Lomb, Rochester, NY, USA) • Flap thickness:
160 and 180 μm
(Sup. H)
130 and 160 μm (Nasal H)
(four groups of eyes)
• Flap diameter: 8.5 mm
• Cochet-Bonnet esthesiometry Q1 month until full recovery
Ghoreishi et al. (99) Hinge position DES Iran, same center, same surgeon 106 (212) • Hansatome zero compression
• Microkeratome (Bausch & Lomb, Rochester, NY, USA): both hinges
Technolas 217 z excimer laser (Bausch & Lomb) • Flap thickness:
• 160 or 180 μm
• Flap diameter:
• 8.5 or 9.5 mm
ü All are determined by the surgeon (based on each individual) but the same in both eyes
• Visual acuity
• Fluorescein tear-film breakup time
• ST (with anesthesia)
• OSDI questionnaire (subjective)
1 week (except OSDI)
1 month
3 months
6 months
Vrom an et al. (90) Hinge position CS and DES USA, same center 47 (94) • Hansatome microkeratome (Bausch & Lomb): superior hinge
• Amadeus microkeratome: nasal hinge
VISX S3 laser • Flap thickness:
180 μm in SH Flap
160 μm in NH Flap
• Flap diameter:
• 8.5 mm
• Hinge width:
• 5.0 mm
• Visual acuity
• Contrast sensitivity
• CS (Cochet-Bonnet corneal esthesiometer)
• Basic secretion test
• TBUT
• OSS (conjunctival and corneal)
• OSDI questionnaire (subjective)
1 week
1 month
3 months
6 months
De Paiva et al. (99) Hinge position CS, DES, visual acuity, and ocular surface parameters USA, same center, three surgeons for surgeries but one surgeon for follow-up, bilateral LASIK and same flap in both eyes of each patient 35 (70) • Hansatome microkeratome (Bausch and Lomb, Rochester, NY, USA): superior hinge
• Amadeus microkeratome (Advanced Medical Optics, Irvine, CA, USA): nasal hinge
VISX Star IV excimer laser (VISX Inc, Santa Clara, CA, USA) • Flap thickness:
• 160 μm
• Flap diameter:
• 9.5 mm
• Corneal surface evaluation
• Optical aberrometer
• Snellen visual Acuity measurement
• TBUT
• CFS
• Belmonte modified noncontact gas esthesiometry (for corneal sensitivity)
• ST
1 week
1 month
3 months
6 months
Mianet al. (91) Hinge position CS and DES USA, same center, university-based academic practice 33 (66) • 30 KHz IntraLase Femtosecond Laser (IntraLase Corp.): both hinges Technolas 217 excimer laser (Bausch & Lomb) • Flap thickness:
• 130 μm
• Flap diameter:
• 9.0 mm
• Hinge angle:
• 45 degrees
• Central cochet-bonnet esthesiometry
• OSDI questionnaire (subjective)
• ST (with anesthesia)
• TBUT
• CFS
• Conjunctival LGS (with a modified Oxford scale)
1 week
1 month
3 months
6 months
12 months
Mian et al. (94) Hinge position, hinge angle and flap thickness CS and DES USA, same center, university-based academic practice 95 (190) • 30 or 60 KHz IntraLase FS laser (IntraLase Corp.): both hinges Technolas 217 excimer laser (Bausch & Lomb) • Flap thickness:
• 100 or 130 μm
• Flap diameter:
• 9.0 mm
• Hinge angle:
• 45 or 90 degrees
• Central cochet-bonnet esthesiometry
• OSDI questionnaire (subjective)
• ST (with anesthesia)
• TBUT
• CFS
• Conjunctival LGS (with a modified Oxford scale)
1 week
1 month
3 months
6 months
12 months
Huang et al. (100) Hinge position CS and DES N/A 43 (86) • Femtosecond laser N/A • superior- versus nasal-hinged flaps • Corneal esthesiometry
• BST
• TBUT
• OSS
• OSDI questionnaire (subjective)
1 week
1 month
3 months
6 months

RR, refractive results; DES, dry eye syndrome; SCMD, standard cubic meters per day; TBUT, tear break-up time; ST, Schirmer test; CS, corneal sensation; LGS, lissamine green staining; DE, dry eye; ACS, automated corneal shaper; OSID, ocular surface disease index; OSS, ocular surface staining; CFS, corneal fluorescein staining; BST, Schirmer basic tear secretion test.