Skip to main content
. 2023 Apr 17;30(2):167–177. doi: 10.5603/CJ.a2021.0154

Table 2.

Baseline lesion and procedural characteristics with available follow-up angiography suitable for Murray law-based quantitative flow ratio (μQFR) analysis after drug-coated balloon (DCB) treatment of in-stent restenosis (ISR).

Variables VOCE (n = 20) Non-VOCE (n = 149) P
Target vessel: 0.81
 RCA 6 (30.00%) 57 (38.26%)
 LAD 11 (55.00%) 70 (46.98%)
 LCX 3 (15.00%) 22 (14.76%)
Ostial lesion 2 (10.00%) 4 (2.68%) 0.15
Bifurcation lesion 5 (25.00%) 47 (31.54%) 0.55
Restenosis pattern: 0.41
 Mehran I 4 (20.00%) 50 (33.56%)
 Mehran II 13 (65.00%) 73 (48.99%)
 Mehran III 3 (15.00%) 26 (17.45%)
Shenqi DCB 11 (55.00%) 78 (52.35%) 0.82
QCA parameters:
 Lesion length [mm] 15.67 ± 5.61 14.99 ± 8.39 0.73
 RVD [mm] 2.37 ± 0.40 2.60 ± 0.42 0.02
 MLD [mm] 0.74 ± 0.35 0.95 ± 0.39 0.02
 DS [%] 67.95 ± 12.10 63.20 ± 12.53 0.11
 DS after DCB [%] 17.58 ± 15.17 21.11 ± 10.10 0.32
Procedural data:
 Predilation 20 (100.00%) 149 (100.00%) > 0.999
 Cutting balloon 5 (25.00%) 38 (25.50%) 0.96
 DCB diameter [mm] 2.87 (2.62–3.50) 3.00 (2.75–3.50) 0.48
 DCB length [mm] 20.00 (20.00–25.50) 20.00 (17.00–26.00) 0.91
 DCB pressure [atm] 9 (8–9) 9 (8–10) 0.60
 DCB Inflation time [s] 60 (60–60) 60 (60–60) > 0.999
 No. of DCB used > 1 1 (5.00%) 3 (2.01%) 0.40
μQFR measurements:
 Baseline μQFR 0.50 (0.37–0.75) 0.77 (0.63–0.85) 0.001
 Post-procedural μQFR 0.88 (0.79–0.94) 0.96 (0.91–0.98) < 0.001
 Post-procedural μQFR ≤ 0.80 6 (30.00%) 6 (4.03%) < 0.001
μQFR improvement 0.30 (0.18–0.41) 0.18 (0.10–0.34) 0.01
Residual lesion after DCB treatment 8 (40.00%) 21 (14.09%) 0.01
Diameter difference DCB — RVD 0.61 (0.43–0.82) 0.43 (0.29–0.59) 0.004
Length difference DCB — lesion 6.36 (2.62–9.32) 7.26 (2.65–11.88) 0.59

Values are expressed as mean ± standard deviation median (25th–75th percentile) or number (%); DS — diameter stenosis; LAD — left coronary artery; LCX — left circumflex coronary artery; MLD — minimum lumen diameter; QCA — quantitative coronary angiography; RCA — right coronary artery; RVD — reference vessel diameter; VOCE — vessel-oriented composite endpoint