Skip to main content
. 2023 Feb 25;14:100208. doi: 10.1016/j.xnsj.2023.100208

Table 1.

Reduction of the number of surgical instruments on the laminectomy tray (LT) and basic neurosurgery tray (BNT) using the clinician review approach, the mathematical Newsvendor model, and the hybrid cost-based point of inflection model.

Laminectomy tray Basic neurosurgery tray
N° instruments (% Size reduction) N° instruments (% Size reduction)
Preoptimization 53 91
Clinician Review 37 (30.19%) 81 (10.99%)
Newsvendor Model 42 (20.75%) 78 (14.29%)
Hybrid Model 36 (32.08%) 85 (6.59%)
Average% Size Reduction (± Standard Deviation) 27.67 (± 6.068) 10.62 (± 3.86)