Skip to main content
. 2023 Mar 21;8(5):101223. doi: 10.1016/j.adro.2023.101223

Table 2.

Mean values and minimum–maximum intervals for CTVTD98%, PTVD98%, and PTV105% calculated using MC and Eclipse algorithms for patients with a chest-wall thickness <15 mm, without and with bolus, and for patients with a chest-wall thickness of 20 to 25 mm without bolus

CTVTD98%, thin chest
Chest wall 20-25 mm
Mean
Range
Mean
Range
Calculation method No bolus With bolus No bolus With bolus No bolus
AAA 70.1 97.6 [–25.3, 32.2] [–2.7, 2.8] 100.2 [–5.2, 3.8]
AXBw 75.0 97.3 [–23.9, 26.9] [–2.6, 2.9] 99.6 [–4.3, 4.6]
MCw 88.0 97.2 [–12.6, 15.4] [–2.3, 2.4] 99.9 [–5.2, 3.6]
AXBm 75.3 96.9 [–24.0, 28.6] [–3.0, 3.4] 99.6 [–5.3, 3.5]
MCm 87.0 96.1 [–13.5, 16.3] [–2.9, 3.0] 99.2 [–5.4, 3.6]
PTVD98%, thin chest
Chest wall 20-25 mm
Mean
Range
Mean
Range
Calculation method No bolus With bolus No bolus With bolus No bolus
AAA 72.0 94.7 [–11.7, 20.1] [–1.6, 1.2] 94.6 [–2.7, 1.1]
AXBw 77.6 94.5 [–9.9, 15.7] [–1.8, 1.1] 94.2 [–2.7, 2.4]
MCw 86.7 94.4 [–5.2, 6.6] [–4.2, 0.5] 94.2 [–2.9, 2.2]
AXBm 77.4 93.4 [–10.5, 14.7] [–1.8, 0.6] 93.4 [–2.5, 1.7]
MCm 84.4 92.7 [–13.6, 7.2] [–3.3, 1.2] 92.9 [–2.9, 1.7]

Abbreviations: CTVT = clinical target volume tumor; MC = Monte Carlo; PTV = planning target volume.

AXBw and MCw denote Acuros XB and MC doses in dose-to-water terms, whereas AXBm and MCm refer to doses in dose-to-medium terms.