Table 2.
Magnetic resonance imaging parameters for the Improving Cognitive Function Through High-Intensity Interval Training in Breast Cancer Patients Undergoing Chemotherapy trial.
Sequence | Flip angle | Voxel size (mm3) | TEa (ms) | TRb (ms) | Acceleration | Extra notes |
3D T1 MPRAGEc | 8 | 0.8 × 0.8 × 0.8 | 2.22 | 2400 | GRAPPAd factor 2 | Inversion time: 1000 ms |
DTIe | 78 | 1.5 × 1.5 × 1.5 | 89.20 | 3930 | None | 107 gradient directions both APf and PAg |
rsfMRIh | 52 | 2.0 × 2.0 × 2.0 | 37.00 | 800 | None | AP direction |
aTE: time to echo.
bTR: time to repetition.
cMPRAGE: magnetization-prepared rapid acquisition with gradient echo.
dGRAPPA: Generalized Autocalibrating Partially Parallel Acquisitions.
eDTI: diffusion tensor imaging.
fAP: anteroposterior.
gPA: posteroanterior.
hrsfMRI: resting-state functional magnetic resonance imaging.